Performance of Open and Closed Cell Laser Cut Nitinol Stents for the Treatment of Chronic Iliofemoral Venous Outflow Obstruction in Patients Treated at a Single Centre

Eur J Vasc Endovasc Surg. 2022 Apr;63(4):613-621. doi: 10.1016/j.ejvs.2021.10.052. Epub 2022 Jan 10.

Abstract

Objective: A number of dedicated self expanding nitinol stents have been developed for use in the venous system, with both open cell (OC) and closed cell (CC) designs available. Data comparing these different designs are lacking. The objective of this study was to evaluate outcomes in patients treated with open and closed cells for unilateral chronic iliac vein obstruction.

Methods: A single centre retrospective cohort study was conducted, including all patients treated with a dedicated nitinol venous stent between 2014 and 2019. Stent patency and details of re-interventions (including lysis, venoplasty, reinforcement, extension, arteriovenous fistula formation) were examined in the first post-operative year. Subgroup analysis described outcomes for patients treated with OC and CC stents ending above the inguinal ligament and those who required extension into the common femoral vein. Cox regression analysis was used to identify factors associated with loss of primary patency.

Results: A total of 207 patients were included (OC 100 patients, CC 107 patients). There was no significant difference between the groups for age (OC 42 years, CC 44 years); gender (OC and CC 67% female); presence of post-thrombotic lesions (OC 71%, CC 73%); stenting across the inguinal ligament (OC 58%, CC 56%), or presence of inflow disease (OC 49%, CC 47%). Primary and cumulative patency at 12 months were similar between groups (primary: OC 63%, CC 65%; cumulative: OC 93%, CC 90%). Patients with a CC stent across the inguinal ligament had a greater risk of needing multiple re-interventions at one year compared with those with an OC stent (odds ratio 2.84, 95% confidence interval [CI] 1.16 - 6.9) but overall, the only factor significantly associated with loss of primary patency was inflow vessel disease (hazard ratio 3.39, 95% CI 1.73 - 6.62, p < .001).

Conclusion: OC and CC dedicated nitinol venous stents were observed to perform similarly in terms of patency and symptom improvement at one year. Disease of the inflow vessels was the most important factor associated with a loss of stent patency irrespective of stent design.

Keywords: Deep vein thrombosis; Iliac vein; Post-thrombotic syndrome; Venous stent.

MeSH terms

  • Adult
  • Alloys
  • Female
  • Humans
  • Iliac Vein* / diagnostic imaging
  • Iliac Vein* / surgery
  • Lasers
  • Male
  • Retrospective Studies
  • Stents
  • Treatment Outcome
  • Vascular Diseases*
  • Vascular Patency

Substances

  • Alloys
  • nitinol