Relation Between Pulmonary Artery Pressures Measured Intraoperatively and at One-Year Catheterization After Unifocalization and Repair of Tetralogy With Major Aortopulmonary Collateral Arteries

Semin Thorac Cardiovasc Surg. 2022 Autumn;34(3):1013-1025. doi: 10.1053/j.semtcvs.2022.01.004. Epub 2022 Jan 31.

Abstract

To assess the relationships between pulmonary artery (PA) pressure and the PA: aortic systolic pressure ratio measured intraoperatively and at surveillance catheterization in patients achieving complete unifocalization and repair for tetralogy of Fallot with major aortopulmonary collateral arteries (TOF/MAPCAs). This was a single-center retrospective cohort analysis of all patients who underwent complete repair of TOF/MAPCAs from 2002 to 2019 and received a postoperative surveillance catheterization at our center 6-24 months after surgery. Associations between intraoperative and catheter hemodynamic data were analyzed. A total of 163 patients were included. Median systolic PA pressure was 30 (quartiles 26, 35) and 35 (28, 42) mm Hg intraoperatively and at catheterization respectively; systolic aortic pressure 90 (86, 100) and 84 (76, 92); and PA:aortic pressure ratio was 0.33 (0.28, 0.40) and 0.41 (0.34, 0.49). Moderate correlation was found between the intraoperative and catheter-based hemodynamics, with the majority of systolic PA pressures within 10 mm Hg and PA:Ao systolic ratios within 0.1. Changes in the ratio were influenced to a similar degree by differences in PA and aortic pressures. Surgical and/or catheter reinterventions were more common in patients with both higher intraoperative PA systolic pressure and PA:aortic systolic ratios and in those with a greater discrepancy between intraoperative and catheterization values. PA systolic pressure and the PA:aortic systolic pressure ratio measured immediately after repair remains useful metrics for assessing the initial operative PA reconstruction, and as indicators of longer-term hemodynamics. Initially elevated and subsequently discrepant PA systolic pressure and PA:aortic systolic pressure ratios were associated with higher rates of reintervention.

Keywords: Hemodynamics; Major aortopulmonary collateral arteries; Tetralogy of fallot; Unifocalization.

MeSH terms

  • Catheterization
  • Collateral Circulation
  • Humans
  • Infant
  • Pulmonary Artery / surgery
  • Pulmonary Atresia* / surgery
  • Retrospective Studies
  • Tetralogy of Fallot* / complications
  • Tetralogy of Fallot* / diagnostic imaging
  • Tetralogy of Fallot* / surgery
  • Treatment Outcome