Objective: This study aimed to compare [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT with [18F]FDG PET/CT in the evaluation of initial gastric cancer.
Methods: We retrospectively compared [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT with [18F]FDG PET/CT in patients with initial gastric cancer from September 2020 to March 2021. Lesion detectability and the uptake of lesions quantified by the maximum standardized uptake value (SUVmax) and target-to-background ratio (TBR) were compared between the two modalities using the Wilcoxon signed-rank test, Mann-Whitney U test, and McNemar's chi-square test.
Results: A total of 61 patients (37 males, aged 23-81 years) were included, of which 22 underwent radical gastrectomy. For primary lesions, higher uptake of [68Ga]Ga-FAPI-04/[18F]FAPI-42 was observed compared to [18F]FDG (median SUVmax, 14.60 vs 4.35, p < 0.001), resulting in higher positive detection using [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT than [18F]FDG PET/CT (95.1% vs 73.8%, p < 0.001), particularly for tumors with signet-ring cell carcinoma (SRCC) (96.4% vs 57.1%, p < 0.001). [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT detected more positive lymph nodes than [18F]FDG PET/CT (637 vs 407). However, both modalities underestimated N staging compared to pathological N staging. [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT showed a higher sensitivity (92.3% vs 53.8%, p = 0.002) and peritoneal cancer index score (18 vs 3, p < 0.001) in peritoneum metastasis and other suspect metastases compared to [18F]FDG PET/CT.
Conclusion: Our findings indicate that [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT outperformed [18F]FDG PET/CT in the evaluation of primary tumors with SRCC and peritoneum metastasis in initial gastric cancer. However, no clinically useful improvement was seen in N staging.
Key points: • The uptake of [68Ga]Ga-FAPI-04/[18F]FAPI-42 in primary tumor and metastasis was intensely higher than that of [18F]FDG (p < 0.001) in 61 patients with initial gastric cancer. • [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT had a higher sensitivity detection in primary tumors (95.1% vs 73.8%, p < 0.001) and peritoneal metastases (92.3% vs 53.8%, p = 0.002) than [18F]FDG PET/CT. • [68Ga]Ga-FAPI-04/[18F]FAPI-42 PET/CT depicted more positive lymph nodes than [18F]FDG PET/CT (637 vs 407); however, both underestimated N staging compared to pathological N staging.
Keywords: Fibroblast activation protein inhibitor; Gastric cancer; PET/CT; [18F]FAPI-42; [68Ga]Ga-FAPI-04.
© 2022. The Author(s), under exclusive licence to European Society of Radiology.