LRP4-IgG service line testing in seronegative myasthenia gravis and controls

J Neuroimmunol. 2022 Jul 15:368:577895. doi: 10.1016/j.jneuroim.2022.577895. Epub 2022 May 18.

Abstract

Background: LRP4 is a post-synaptic membrane protein that promotes acetylcholine (AChR) clustering on the crest of post-synaptic neuromuscular folds. Autoantibodies against LRP4 are suggested to account for myasthenia gravis (MG) patients negative for antibodies to AChR.

Objectives: To report a clinical experience with service-line LRP4-IgG cell-based testing in electrodiagnostically confirmed MG patients and controls.

Methods: We identified all Mayo patients undergoing MG evaluations with send out LRP4-IgG antibody testing by cell-based assay, having clinical-electrodiagnostic (EDX) testing. To be included, muscle acetylcholine receptor binding (AChR-Bi) and muscle-specific tyrosine kinase (MuSK) antibodies had to be absent prior to LRP4-IgG testing. Follow-up AChR-Bi antibody testing was reviewed. Also tested for LRP4-IgGs were 119 healthy subjects.

Results: Identified were 25 generalized MG, 24 ocular MG, and 55 patients initially considered to have MG prior to negative EDX testing. No seronegative patients with EDX confirmed MG had LRP4-IgG positivity but five non-MG patients did: Guillain-Barre syndrome with fatigue (N = 1); multiple cranial neuropathies (N = 1); functional neurologic disorders (N = 3). Of healthy subjects, 4% (5/119) were LRP4-IgG positive (N = 5) or had a borderline result (N = 1). Of MG patients with repeat AChR-Bi testing, 40% (10/25) seroconverted (5 with ocular MG and 5 with generalized MG) (median AChR IgG value: 0.34 nmol/L, range 0.2-20.9 nmol/L, median followup 26 months, range 2-72 months).

Conclusion: Clinical review of LRP4-IgG commercial cell-based testing suggests lack of diagnostic utility in seronegative EDX-confirmed MG. The clinical utility of LRP4-IgG testing is not substantiated in service line testing. In contrast, repeat testing for AChR-Bi antibodies is shown clinically useful.

Keywords: Accuracy; LRP4; Myasthenia gravis.

MeSH terms

  • Acetylcholine
  • Autoantibodies
  • Humans
  • Immunoglobulin G / metabolism
  • LDL-Receptor Related Proteins* / metabolism
  • Myasthenia Gravis*
  • Protein Binding

Substances

  • Autoantibodies
  • Immunoglobulin G
  • LDL-Receptor Related Proteins
  • LRP4 protein, human
  • Acetylcholine