Angiographic predictors of aberrant circumflex artery during cardiac catheterization

Catheter Cardiovasc Interv. 2022 Sep;100(3):378-386. doi: 10.1002/ccd.30322. Epub 2022 Jul 12.

Abstract

Objectives: To identify angiographic predictors of aberrant left circumflex artery (LCx) by comparing left main (LM) length and bifurcation angle between patients with aberrant LCx and normal anatomy.

Background: Failure to recognize aberrant LCx during a cardiac catheterization may hamper correct diagnosis, delay intervention in acute coronary syndromes, and result in increased contrast volume, radiation exposure, and infarct size.

Methods: We retrospectively analyzed angiograms of aberrant LCx patients and normal anatomy matched controls, in three-participating centers. LM-length, bifurcation angle between the left anterior descending (LAD) and the first non-LAD branch of the LM, and procedural data were compared.

Results: Between 2003 and 2020, 136 patients with aberrant LCx and 135 controls were identified. More catheters (2.4 ± 0.6 vs. 2.2 ± 0.9, p = 0.009), larger contrast volumes (169 ± 94 ml vs. 129 ± 68 ml, p < 0.0005), and prolonged fluoroscopy time (652.9 ± 623.7 s vs. 393.1 ± 332.1 s, p < 0.0005), were required in the aberrant LCx-group compared with controls. Patients with aberrant LCx had a longer LM-length and a more acute bifurcation angle, both in caudal and cranial views, compared with controls (24.7 ± 8.1 vs. 10.8 ± 4.5 mm, p < 0.0005 and 26.7 ± 7.4 vs. 12 ± 5.5 mm, p < 0.0005, respectively, and 45.2° ± 12° vs. 88.8° ± 23°, p < 0.0005 and 51.9° ± 21° vs. 68.2° ± 28.3°, p < 0.0005, respectively). In ROC analysis, LM-length showed the best diagnostic accuracy for detecting aberrant LCx. In multiple logistic regression analysis, a cranially measured LM-length > 17.7 mm was associated with a 5.3 times greater probability of predicting aberrant LCx [95% CI (3.4-8.1), p < 0.0001].

Conclusions: Our study suggests that a long LM-length and an acute bifurcation angle can indicate the presence of aberrant LCx. We present a practical algorithm for its rapid identification.

Keywords: aberrant circumflex; bifurcation angle; contrast volume; coronary; fluoroscopy time; left main length.

MeSH terms

  • Cardiac Catheterization / adverse effects
  • Coronary Angiography
  • Coronary Artery Disease* / diagnostic imaging
  • Coronary Artery Disease* / therapy
  • Coronary Vessels / diagnostic imaging
  • Humans
  • Retrospective Studies
  • Treatment Outcome
  • Vascular Malformations*