Small incision lenticule extraction (SMILE), with over 5 million procedures globally performed, will challenge ophthalmologists in the foreseeable future with accurate intraocular lens power calculations in an ageing population. After more than one decade since the introduction of SMILE, only one case report of cataract surgery with IOL implantation after SMILE is present in the peer-reviewed literature. Hence, the scope of the present multicenter study was to compare the IOL power calculation accuracy in post-SMILE eyes between ray tracing and a range of empirically optimized formulae available in the ASCRS post-keratorefractive surgery IOL power online calculator. In our study of 11 post-SMILE eyes undergoing cataract surgery, ray tracing showed the smallest mean absolute error (0.40 D) and yielded the largest percentage of eyes within ±0.50/±1.00 D (82/91%). The next best conventional formula was the Potvin-Hill formula with a mean absolute error of 0.66 D and an ±0.50/±1.00 D accuracy of 45 and 73%, respectively. Analyzing this first cohort of post-SMILE eyes undergoing cataract surgery and IOL implantation, ray tracing showed superior predictability in IOL power calculation over empirically optimized IOL power calculation formulae that were originally intended for use after Excimer-based keratorefractive procedures.
Keywords: IOL calculation; SMILE; cataract surgery; ray tracing.