Optimal Temporal Resolution to Achieve Good Image Quality and Perform Pharmacokinetic Analysis in Free-breathing Dynamic Contrast-enhanced MR Imaging of the Pancreas

Magn Reson Med Sci. 2023 Oct 1;22(4):477-485. doi: 10.2463/mrms.mp.2022-0035. Epub 2022 Aug 23.

Abstract

Purpose: The optimal temporal resolution for free-breathing dynamic contrast-enhanced MRI (FBDCE-MRI) of the pancreas has not been determined. This study aimed to evaluate the appropriate temporal resolution to achieve good image quality and to perform pharmacokinetic analysis in FBDCE-MRI of the pancreas using golden-angle radial sparse parallel (GRASP).

Methods: Sixteen participants (53 ± 15 years, eight females) undergoing FBDCE-MRI were included in this prospective study. Images were retrospectively reconstructed at four temporal resolutions (1.8, 3.0, 4.8, and 7.8s). Two radiologists (5 years of experience) evaluated the image quality of each reconstructed image by assessing the visualization of the celiac artery (CEA), the common hepatic artery, the splenic artery, each area of the pancreas, and artifacts using a 5-point scale. Using Tissue-4D, pharmacokinetic parameters were calculated for each area in the reconstructed images at each temporal resolution for 16 examinations, excluding two with errors in the pharmacokinetic modeling analysis. Friedman and Bonferroni tests were used for analysis. A P value < 0.05 was considered statistically significant.

Results: During vascular assessment, only scores for the CEA at 7.8s were significantly lower than the other temporal resolutions. Scores of all pancreatic regions and artifacts were significantly lower at 1.8s than at 4.8s and 7.8s. In the pharmacokinetic analysis, all volume transfer coefficients (Ktrans), rate constants (Kep), and the initial area under the concentration curve (iAUC) in the pancreatic head and tail were significantly lower at 4.8s and 7.8s than at 1.8s. iAUC in the pancreatic body and extracellular extravascular volume fraction (Ve) in the pancreatic head were significantly lower at 7.8s than at 1.8s.

Conclusion: A temporal resolution of 3.0s is appropriate to achieve image quality and perform pharmacokinetic analysis in FBDCE-MRI of the pancreas using GRASP.

Keywords: dynamic contrast-enhanced magnetic resonance imaging; golden-angle radial sparse parallel; image quality; pharmacokinetic analysis; temporal resolution.

MeSH terms

  • Contrast Media* / pharmacokinetics
  • Female
  • Humans
  • Image Enhancement* / methods
  • Magnetic Resonance Imaging / methods
  • Pancreas / diagnostic imaging
  • Prospective Studies
  • Retrospective Studies

Substances

  • Contrast Media

Grants and funding

This work was supported by the Japan Society for the Promotion of Science for grant support (JSPS KAKENHI grant Number 20K07992) and Bayer Yakuhin for grant support (Bayer Academic Support application number BASJ20210406008).