Application of the hybrid algorithm for the treatment of coronary chronic total occlusions requires the operator to readily deploy complex techniques and advanced technologies to achieve successful revascularization. Patient-specific factors and limitations in torquability and material strength of low-profile equipment such as microcatheters can result in procedural complications due to device fracture. Using a mini-series of 2 cases to demonstrate the successful application of antegrade dissection re-entry techniques to overcome such challenges, we highlight procedural complexities and risk, and review prior approaches and literature.
Keywords: CTO-PCI; complications; coronary chronic total occlusion; stenting.