Background: Kissing balloon inflation with distal guide wire recross can cause severe stent deformation depending on the stent link location with respect to the carina. The balloon-push technique, by which an inflated balloon is forced into the SB from the proximal main vessel (MV), is a feasible way to remove jailed struts without causing severe stent deformation.
Aims: We investigated the procedural success rate, patterns of jailed strut removal at side branch (SB) orifices, factors related to failure of jailed strut removal, and follow-up angiogram results of the balloon-push technique.
Methods: Between September 2015 and December 2020, 51 bifurcation stenting cases in which the balloon-push technique was used were enrolled. Based on three-dimensional optical coherence tomography images, strut removal with 1 stent crown length was defined as successful. Strut removal patterns were classified into two types: parallel-slide type (stent struts shifted distally into the MV lumen without inversion) and under-carina type (stent struts shifted distally under the carina with strut inversion or strut slide).
Results: Procedural success was attained in 39 cases (success rate: 76.5%). Parallel-slide type and under-carina type occurred in 43% and 33% of cases, respectively. Factors related to failure were trifurcation lesions and a smaller pushed balloon-SB artery ratio compared with those in success cases (0.95 ± 0.18 vs. 1.10 ± 0.22, p = 0.032). Follow-up angiography was performed in 37 cases, and 2 cases had binary in-stent restenosis.
Conclusions: Removal of jailed struts with the balloon-push technique was feasible, without severe stent deformation, in bifurcation stentings.
Keywords: balloon-push technique; bifurcation stenting; three-dimensional optical coherence tomography.