Comparative clinical efficacy and safety of insulin glargine 300 U/ml (Toujeo) versus insulin glargine 100 U/ml in type 2 diabetes and type 1 diabetes: A systematic literature review and meta-analysis

Diabetes Obes Metab. 2023 Jun;25(6):1589-1606. doi: 10.1111/dom.15007. Epub 2023 Feb 28.

Abstract

Aim: To compare the clinical efficacy and safety of glargine-U100 (Lantus/Gla-100) with glargine-U300 (Toujeo/Gla-300) in adult patients with type 2 diabetes (T2D) and type 1 diabetes (T1D).

Materials and methods: A literature search on Gla-300/Gla-100 in diabetes management was conducted using the MEDLINE/Embase/Cochrane databases from inception to 10 January 2021. Eligible studies considered for inclusion were parallel-design, randomized controlled trials (RCTs). The Cochrane risk-of-bias tool was used to evaluate the quality of the included studies. The random-effects model was applied for interpretation of the results.

Results: Of 5348 records screened, 592 were assessed for eligibility and 15 RCTs were considered for data extraction and meta-analysis (T2D [N = 10; n = 7082]; T1D [N = 5; n = 2222]). In patients with T1D, all safety parameters were comparable between Gla-100 and Gla-300. In T2D, statistically significant differences were observed in favour of Gla-300 over Gla-100 for nocturnal and total hypoglycaemia. For efficacy parameters, a statistically and clinically significant difference favouring Gla-100 in basal insulin dose requirement was observed for both T2D and T1D. Change in HbA1c showed a statistically but not clinically significant reduction with Gla-100 compared with Gla-300 in T1D. Statistically significant but clinically less relevant differences favoured Gla-300 for control of body weight in T1D and T2D and Gla-100 for fasting blood glucose in T2D.

Conclusions: Gla-100 and Gla-300 had comparable efficacy and safety profiles in both T1D and T2D populations. Gla-300 showed a lower risk of nocturnal and total hypoglycaemia, significant in insulin-experienced/exposed patients with T2D. Patients on Gla-300 required significantly more units of insulin daily than the Gla-100 group to achieve equivalent efficacy.

Keywords: antidiabetic drug; meta-analysis; systematic review; type 1 diabetes; type 2 diabetes.

Publication types

  • Comparative Study
  • Meta-Analysis
  • Systematic Review
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Blood Glucose
  • Diabetes Mellitus, Type 1* / drug therapy
  • Diabetes Mellitus, Type 2* / drug therapy
  • Glycated Hemoglobin
  • Humans
  • Hypoglycemia* / chemically induced
  • Hypoglycemia* / prevention & control
  • Hypoglycemic Agents / adverse effects
  • Insulin Glargine / adverse effects
  • Insulin, Regular, Human
  • Treatment Outcome

Substances

  • Blood Glucose
  • Glycated Hemoglobin
  • Hypoglycemic Agents
  • Insulin Glargine
  • Insulin, Regular, Human