Assessing the variability and correlation between SUV and ADC parameters of head and neck cancers derived from simultaneous PET/MRI: A single-center study

J Appl Clin Med Phys. 2023 May;24(5):e13928. doi: 10.1002/acm2.13928. Epub 2023 Feb 10.

Abstract

Objective: Intratumoral heterogeneity is associated with poor outcomes in head and neck cancer (HNC) patients owing to chemoradiotherapy resistance. [18 F]-FDG positron emission tomography (PET) / Magnetic Resonance Imaging (MRI) provides spatial information about tumor mass, allowing intratumor heterogeneity assessment through histogram analysis. However, variability in quantitative PET/MRI parameter measurements could influence their reliability in assessing patient prognosis. Therefore, to use standardized uptake value (SUV) and apparent diffusion coefficient (ADC) parameters for assessing tumor response, this study aimed to measure SUV and ADC's variability and assess their relationship in HNC.

Methods: First, ADC variability was measured in an in-house diffusion phantom and in five healthy volunteers. The SUV variability was only measured with the NEMA phantom using a clinical imaging protocol. Furthermore, simultaneous PET/MRI data of 11 HNC patients were retrospectively collected from the National Cyclotron and PET center in Chulabhorn Hospital. Tumor contours were manually drawn from PET images by an experienced nuclear medicine radiologist before tumor volume segmentation. Next, SUV and ADC's histogram were used to extract statistic variables of ADC and SUV: mean, median, min, max, skewness, kurtosis, and 5th , 10th , 25th , 50th , 75th , 90th , and 95th percentiles. Finally, the correlation between the statistic variables of ADC and SUV, as well as Metabolic Tumor volume and Total Lesion Glycolysis parameters was assessed using Pearson's correlation.

Results: This pilot study showed that both parameters' maximum coefficient of variation was 13.9% and 9.8% in the phantom and in vivo, respectively. Furthermore, we found a strong and negative correlation between SUVmax and ADVmed (r = -0.75, P = 0.01).

Conclusion: The SUV and ADC obtained by simultaneous PET/MRI can be potentially used as an imaging biomarker for assessing intratumoral heterogeneity in patients with HNC. The low variability and relationship between SUV and ADC could allow multimodal prediction of tumor response in future studies.

Keywords: SUV; and ADC; head and neck cancer; intratumoral heterogeneity; simultaneous PET/MRI.

MeSH terms

  • Fluorodeoxyglucose F18
  • Head and Neck Neoplasms* / diagnostic imaging
  • Humans
  • Magnetic Resonance Imaging* / methods
  • Pilot Projects
  • Positron-Emission Tomography / methods
  • Radiopharmaceuticals
  • Reproducibility of Results
  • Retrospective Studies

Substances

  • Fluorodeoxyglucose F18
  • Radiopharmaceuticals