Production of Co-58m in a siphon-style liquid target on a medical cyclotron

Appl Radiat Isot. 2023 May:195:110734. doi: 10.1016/j.apradiso.2023.110734. Epub 2023 Feb 26.

Abstract

We present the production of 58mCo on a small, 13 MeV medical cyclotron utilizing a siphon style liquid target system. Different concentrated iron(III)-nitrate solutions of natural isotopic distribution were irradiated at varying initial pressures and subsequently separated by solid phase extraction chromatography. The radio cobalt (58m/gCo and 56Co) was successfully produced with saturation activities of (0.35 ± 0.03) MBq μA-1 for 58mCo with a separation recovery of (75 ± 2) % of cobalt after one separation step utilizing LN-resin.

Keywords: Cobalt-58m; Cyclotron production; Liquid target; Meitner-Auger therapy; Radiometal; Small medical cyclotron.