Aims: To evaluate the efficacy of oesophageal cooling in the prevention of oesophageal injury in patients undergoing atrial fibrillation (AF) catheter ablation.
Methods and results: Comprehensive search of MEDLINE, EMBASE, and Cochrane databases through April 2022 for randomized controlled trials (RCTs) evaluating the role of oesophageal cooling compared with control in the prevention of oesophageal injury during AF catheter ablation. The study primary outcome was the incidence of any oesophageal injury. The meta-analysis included 4 RCTs with a total of 294 patients. There was no difference in the incidence of any oesophageal injury between oesophageal cooling and control [15% vs. 19%; relative risk (RR) 0.86; 95% confidence interval (CI) 0.31-2.41]. Compared with control, oesophageal cooling showed lower risk of severe oesophageal injury (1.5% vs. 9%; RR 0.21; 95% CI 0.05-0.80). There were no significant differences among the two groups in mild to moderate oesophageal injury (13.6% vs. 12.1%; RR 1.09; 95% CI 0.28-4.23), procedure duration [standardized mean difference (SMD) -0.03; 95% CI -0.36-0.30], posterior wall radiofrequency (RF) time (SMD 0.27; 95% CI -0.04-0.58), total RF time (SMD -0.50; 95% CI -1.15-0.16), acute reconnection incidence (RR 0.93; 95% CI 0.02-36.34), and ablation index (SMD 0.16; 95% CI -0.33-0.66).
Conclusion: Among patients undergoing AF catheter ablation, oesophageal cooling did not reduce the overall risk of any oesophageal injury compared with control. Oesophageal cooling might shift the severity of oesophageal injuries to less severe injuries. Further studies should evaluate the long-term effects after oesophageal cooling during AF catheter ablation.
Keywords: Atrial fibrillation; Catheter ablation; Oesophageal cooling; Oesophageal injury; Radiofrequency ablation.
© The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology.