Purpose: To evaluate the diagnostic performance of myocardium-to-lumen R1 (1/T1) ratio on postcontrast T1 maps for the detection of cardiac amyloidosis in a large patient sample.
Materials and methods: This retrospective study included consecutive patients who underwent MRI-derived extracellular volume fraction (MRI ECV) analysis between March 2017 and July 2021 because of known or suspected heart failure or cardiomyopathy. Pre- and postcontrast T1 maps were generated using the modified Look-Locker inversion recovery sequence. Diagnostic performances of MRI ECV and myocardium-to-lumen R1 ratio on postcontrast T1 maps (a simplified index not requiring a native T1 map and hematocrit level data) for detecting cardiac amyloidosis were evaluated using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity.
Results: Of 352 patients (mean age, 63 years ± 16 [SD]; 235 men), 136 had cardiac amyloidosis. MRI ECV showed 89.0% (121 of 136; 95% CI: 82%, 94%) sensitivity and 98.6% (213 of 216; 95% CI: 96%, 100%) specificity for helping detect cardiac amyloidosis (cutoff value of 40% [AUC, 0.99 {95% CI: 0.97, 1.00}; P < .001]). Postcontrast myocardium-to-lumen R1 ratio showed 92.6% (126 of 136; 95% CI: 89%, 96%) sensitivity and 93.1% (201 of 216; 95% CI: 89%, 96%) specificity (cutoff value of 0.84 [AUC, 0.98 {95% CI: 0.95, 0.99}; P < .001]). There was no evidence of a difference in AUCs for each parameter (P = .10).
Conclusion: Postcontrast myocardium-to-lumen R1 ratio showed excellent diagnostic performance comparable to that of MRI ECV in the detection of cardiac amyloidosis.Keywords: MR Imaging, Cardiac, Heart, Cardiomyopathies Supplemental material is available for this article. © RSNA, 2023.
Keywords: Cardiac; Cardiomyopathies; Heart; MR Imaging.
© 2023 by the Radiological Society of North America, Inc.