Flexible, high-resolution cortical arrays with large coverage capture microscale high-frequency oscillations in patients with epilepsy

Epilepsia. 2023 Jul;64(7):1910-1924. doi: 10.1111/epi.17642. Epub 2023 May 17.

Abstract

Objective: Effective surgical treatment of drug-resistant epilepsy depends on accurate localization of the epileptogenic zone (EZ). High-frequency oscillations (HFOs) are potential biomarkers of the EZ. Previous research has shown that HFOs often occur within submillimeter areas of brain tissue and that the coarse spatial sampling of clinical intracranial electrode arrays may limit the accurate capture of HFO activity. In this study, we sought to characterize microscale HFO activity captured on thin, flexible microelectrocorticographic (μECoG) arrays, which provide high spatial resolution over large cortical surface areas.

Methods: We used novel liquid crystal polymer thin-film μECoG arrays (.76-1.72-mm intercontact spacing) to capture HFOs in eight intraoperative recordings from seven patients with epilepsy. We identified ripple (80-250 Hz) and fast ripple (250-600 Hz) HFOs using a common energy thresholding detection algorithm along with two stages of artifact rejection. We visualized microscale subregions of HFO activity using spatial maps of HFO rate, signal-to-noise ratio, and mean peak frequency. We quantified the spatial extent of HFO events by measuring covariance between detected HFOs and surrounding activity. We also compared HFO detection rates on microcontacts to simulated macrocontacts by spatially averaging data.

Results: We found visually delineable subregions of elevated HFO activity within each μECoG recording. Forty-seven percent of HFOs occurred on single 200-μm-diameter recording contacts, with minimal high-frequency activity on surrounding contacts. Other HFO events occurred across multiple contacts simultaneously, with covarying activity most often limited to a .95-mm radius. Through spatial averaging, we estimated that macrocontacts with 2-3-mm diameter would only capture 44% of the HFOs detected in our μECoG recordings.

Significance: These results demonstrate that thin-film microcontact surface arrays with both highresolution and large coverage accurately capture microscale HFO activity and may improve the utility of HFOs to localize the EZ for treatment of drug-resistant epilepsy.

Keywords: drug-resistant epilepsy; high-frequency oscillations; interictal; intraoperative; microelectrocorticography.

Publication types

  • Research Support, U.S. Gov't, Non-P.H.S.
  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Brain
  • Brain Waves*
  • Drug Resistant Epilepsy* / diagnosis
  • Drug Resistant Epilepsy* / surgery
  • Electroencephalography / methods
  • Epilepsy* / diagnosis
  • Epilepsy* / surgery
  • Humans

Grants and funding