Background: Short-term continuous flow (STCF) ventricular assist devices (VADs) are utilized in adults with cardiogenic shock; however, mortality remains high. Previous studies have found that high pre-operative MELD-XI scores in durable VAD patients are associated with mortality. The use of the MELD-XI score to predict outcomes in STCF-VAD patients has not been explored. We sought to determine the relationship between MELD-XI and outcomes in adults with STCF-VADs.
Methods: This was a retrospective review of adults implanted with STCF-VADs between 2009 and 2019. Receiver operating characteristic (ROC) analysis was performed to predict outcomes and Kaplan-Meier analysis was done to assess survival.
Results: Seventy-nine patients were included with a median MELD-XI score of 21.2 (IQR 13.5, 27.0). Patients with an unsuccessful wean from support (p < 0.001) or major post-operative bleeding (p = 0.03) had significantly higher pre-implant MELD-XI scores. The optimal MELD-XI cut-point for mortality was 24.9 with 27.8 for major bleeding. Survival was worse among patients in the high-risk MELD-XI group, however, not statistically significant (p = 0.09). Prior ECMO support, but not MELD-XI, was an independent predictor of unsuccessful wean (p = 0.03).
Conclusions: Pre-operative MELD-XI score was a moderate predictor of unsuccessful wean with limited utility in predicting bleeding in patients on STCF-VAD support. This scoring system may be useful in the clinical setting for pre-implant risk stratification and counseling among patients and outcomes.
Keywords: MELD-XI; heart failure; outcomes; temporary support; ventricular assist devices.
© 2023 The Authors. Artificial Organs published by International Center for Artificial Organ and Transplantation (ICAOT) and Wiley Periodicals LLC.