Background: French guidelines for the prevention of vascular access infections in a haemodialysis setting were released in 2005. Compliance with these guidelines is currently unknown. The aim of this study was to assess compliance with the guidelines for vascular access infection prevention in French haemodialysis units, and to describe the difficulties reported.
Methods: A cross-sectional survey was conducted between March and December 2019 in 200 haemodialysis units in France, selected at random. Data were collected via questionnaire, completed by telephone interview with an infection control practitioner. A practice was deemed compliant when >85% of units declared that they always complied with the guidelines.
Results: In total, 103 units (51.5%) agreed to participate. Most practices complied with the guidelines; however, some practices did not reach the 85% compliance threshold for working in pairs when connecting central venous catheter (CVC) lines, performing hand hygiene before disconnecting lines, rinsing antiseptic soap before painting CVC exit site or arteriovenous fistula (AVF) puncture site, allowing antiseptic paint to dry, handling CVC branches with antiseptic impregnated gauze, performing hand hygiene after AVF compression with gloves, wearing protective eyewear when connecting/disconnecting CVC or when puncturing AVF, and wearing a gown when puncturing AVF. The most frequently reported difficulties were understaffing, difficulties with skin preparation because of exit site skin damage, and lack of buttonhole technical expertise.
Conclusions: Despite good overall compliance, this survey highlights some shortcomings in compliance with infection prevention guidelines, which could be associated with either higher risk of vascular access infection or increased blood-borne virus transmission.
Keywords: Bacteraemia; Compliance; Guidelines; Haemodialysis units; Infection control; Vascular access.
Copyright © 2023 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.