Active and passive respiratory mechanics in anesthetized dogs

J Appl Physiol (1985). 1986 Nov;61(5):1647-55. doi: 10.1152/jappl.1986.61.5.1647.

Abstract

In six spontaneously breathing anesthetized dogs (pentobarbital sodium, 30 mg/kg) airflow, volume, and tracheal and esophageal pressures were measured. The active and passive mechanical properties of the total respiratory system, lung, and chest wall were calculated. The average passive values of respiratory system, lung, and chest wall elastances amounted to, respectively, 50.1, 32.3, and 17.7 cmH2O X l-1. Resistive pressure-vs.-flow relationships for the relaxed respiratory system, lung, and chest wall were also determined; a linear relationship was found for the former (the total passive intrinsic resistance averaged 4.1 cmH2O X l-1 X s), whereas power functions best described the others: the pulmonary pressure-flow relationship exhibited an upward concavity, which for the chest wall presented an upward convexity. The average active elastance and resistance of the respiratory system were, respectively, 64.0 cmH2O X l-1 and 5.4 cmH2O X l-1 X s. The greater active impedance reflects pressure losses due to force-length and force-velocity properties of the inspiratory muscles and those due to distortion of the respiratory system from its relaxed configuration.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Anesthesia*
  • Animals
  • Dogs
  • Esophagus
  • Lung / physiology
  • Pentobarbital
  • Pressure
  • Respiration*
  • Thorax
  • Trachea

Substances

  • Pentobarbital