Background: Highly sensitized patients face many barriers to kidney transplantation, including higher rates of antibody-mediated rejection after HLA-incompatible transplant. IdeS, an endopeptidase that cleaves IgG nonspecifically, has been trialed as desensitization prior to kidney transplant, and successfully cleaves donor-specific antibody (DSA), albeit with rebound.
Methods: IdeS was generated and tested (2 mg/kg, IV) in two naïve and four allosensitized nonhuman primates (NHP). Peripheral blood samples were collected at regular intervals following IdeS administration. Total IgG, total IgM, and anti-CMV antibodies were quantified with ELISA, and donor-specific antibody (DSA) and anti-pig antibodies were evaluated using flow cytometric crossmatch. B cell populations were assessed using flow cytometry.
Results: IdeS successfully cleaved rhesus IgG in vitro. In allosensitized NHP, robust reduction of total, DSA, anti-pig, and anti-CMV IgG was observed within one day following IdeS administration. Rapid rebound of all IgG antibody populations was observed, with antibody levels returning to baseline around day 14 post-infusion. Total IgM level was not affected by IdeS. Interestingly, a comparable reduction in antibody populations was observed after the second dose of IdeS. However, we have not observed any significant modulation of B cell subpopulations after IdeS.
Conclusions: This study evaluated efficacy of IdeS in the allosensitized NHP in IgG with various specificities, mirroring antibody kinetics in human patients. The efficacy of IdeS on preexisting anti-pig antibodies may be useful in clinical xenotransplantation. However, given the limitation of IdeS on its durability as a monotherapy, optimization of IdeS with other agents targeting the humoral response is further needed.
Keywords: IdeS; desensitization; immunoglobulin G; rhesus macaque; sensitization.