Introduction: This study aimed to assess the transfer accuracy of a digital indirect bonding method for lingual brackets using double vacuum-formed trays in vivo.
Methods: Twenty-five patients in need of lingual orthodontic treatment were consecutively recruited. Bracket placement was performed on ideal setups, followed by fabricating indirect bonding trays through vacuum-forming on 3-dimensional printed models. Transfer accuracy was measured at each bracket after superimpositions of postbonding scans and reference data. One-tailed t tests were used to determine whether bracket deviations were within the limit of 0.5 mm and 2° for linear and angular dimensions, respectively.
Results: A total of 611 lingual brackets were evaluated. Mean linear transfer errors were 0.06 mm, 0.09 mm, and 0.12 mm, with frequencies of deviations within the 0.5 mm limit of 99.7%, 99.8%, and 98.0% for mesiodistal, buccolingual, and occlusogingival dimensions, respectively. Regarding angular measurements, mean transfer errors were 1.28°, 1.73°, and 2.96°, with frequencies of deviations within the 2° limit of 81.0%, 68.9%, and 51.1% for rotation, tip, and torque, respectively. Mean errors fell within the clinically accepted limits for all linear dimensions and rotation but exceeded the limit for tip and torque.
Conclusions: Lingual bracket indirect bonding using double vacuum-formed trays fabricated on 3-dimensional printed models has high transfer accuracy in the mesiodistal, buccolingual, and occlusogingival dimensions and rotation. However, the transfer of tip and torque is less accurate.