Objective: Pneumothorax (PTX) is a potentially life-threatening condition that affects neonates, with an incidence of 0.05 to 2%. Its management includes conservative treatment, chest tube (CT) drainage, and needle aspiration (NA). Aims were to evaluate the incidence of PTX in a 10-hospital perinatal network, its clinical characteristics and risk factors, and to compare the different treatment options.
Study design: All neonates diagnosed with PTX and hospitalized in the network were included in this retrospective observational trial over a period of 30 months. Primary outcome was the incidence of PTX. Secondary outcomes were the treatment modality, the length of stay (LOS), and the number of chest X-rays.
Results: Among the 173 neonates included, the overall incidence of PTX was 0.56 per 100 births with a large range among the hospitals (0.12-1.24). Thirty-nine percent of pneumothoraces were treated conservatively, 41% by CT drainage, 13% by NA, and 7% by combined treatment. Failure rate was higher for NA (37%) than for CT drainage (9%). However, the number of X-rays was lower for patients treated by NA, with a median of 6 (interquartile range [IQR] 4-6.25), than by CT drainage, with a median of 9 (IQR 7-12). LOS was shorter for NA than for CT drainage, with a median of 2 (IQR 1-4.25) and 6 days (IQR 3-15), respectively. Complications, including apnea and urinary retention, occurred in 28% of patients managed with CT drainage, whereas none was observed with NA.
Conclusion: High variability of PTX incidence was observed among the hospitals within the network, but these values correspond to the literature. NA showed to reduce the number of X-rays, the LOS, and complications compared with CT drainage, but it carries a high failure rate. This study helped provide a new decisional management algorithm to harmonize and improve PTX treatment within our network.
Key points: · Neonatal PTX is a frequent pathology with a high incidence requiring urgent management.. · We report a large variability of PTX incidence between different hospitals of the same network.. · Needle aspiration carries higher failure rate, shorter hospital stay duration without complications reported..
The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).