Purpose: The occurrence of an iatrogenic vertebral fracture during non-spinal digestive surgery is an exceptional event that has not been previously documented. Our study aims to explain the occurrence of this fracture from a biomechanical perspective, given its rarity. Using a finite element model of the spine, we will evaluate the strength required to induce a vertebral fracture through a hyperextension mechanism, considering the structure of the patient's spine, whether it is ossified or healthy.
Methods: A 70-year-old patient was diagnosed T12 fracture during a liver transplantation on ankylosed spine. We use a finite element model of the spine. Different mechanical properties were applied to the spine model: first to a healthy spine, the second to a osteoporotic ossified spine. The displacement and force imposed at the Sacrum, the time and location of fractures initiation were recorded and compared between the two spine conditions.
Results: A surgical treatment is done associating decompression with posterior fixation. After biomechanical study, we found that the fracture initiation occurred for the ossified spine after a sacrum displacement of 29 mm corresponding to an applied force of 65 N. For the healthy spine it occurred at a sacrum displacement of 52 mm corresponding to an applied force of 350 N.
Conclusion: The force required to produce a type B fracture in an ankylosed spine is 5 times less than in a healthy spine. These data enable us to propose several points of management to avoid unexpected complications with ankylosed spines during surgical procedures.
Level of evidence: IV.
Keywords: Ankylosed spine; Biomechanical analysis; Fracture; Iatrogenic.
© 2024. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.