Prediction of bowel necrosis by reduced bowel wall enhancement in closed-loop small bowel obstruction: Quantitative methods

Eur J Radiol. 2024 Apr:173:111363. doi: 10.1016/j.ejrad.2024.111363. Epub 2024 Feb 13.

Abstract

Purpose: To assess diagnostic performance and reproducibility of reduced bowel wall enhancement evaluated by quantitative methods using CT to identify bowel necrosis among closed-loop small bowel obstruction (CL-SBO) patients.

Methods: This retrospective single-center study included patients who diagnosed with CL-SBO caused by adhesion or internal hernia during January 2016 and May 2022. Patients were divided into necrotic group (n = 41) and non-necrotic group (n = 67) according to surgical exploration and postoperative pathology. Two doctors independently measured the attenuation of bowel wall and consensus was reached through panel discussion with a third gastrointestinal radiologist. Reduced bowel wall enhancement was assessed by four quantitative methods. Univariate analyses were used to evaluate the association between each method and bowel necrosis, and kappa/intraclass correlation coefficient values were used to assess interobserver agreement. Diagnostic performance parameters were calculated for each method.

Results: Reduced bowel wall enhancement in arterial phase (OR 8.98, P < 0.0001), reduced bowel wall enhancement in portal phase (OR 16.84, P < 0.001), adjusted reduced bowel wall enhancement in arterial phase (OR 29.48, P < 0.001), adjusted reduced bowel wall enhancement in portal phase (OR 145.69, P < 0.001) were significantly associated with bowel necrosis. Adjusted reduced bowel wall enhancement in portal phase had the best diagnostic performance (AUC: 0.92; Youden index: 0.84; specificity: 94.03 %) and interobserver agreement (kappa value of 0.59-0.73) to predict bowel necrosis.

Conclusion: When assessing reduced bowel enhancement to predict bowel necrosis among CL-SBO patients, using unenhanced CT images and proximal dilated loop as standard references in portal phase is the most accurate quantitative method among those tested.

Keywords: Bowel necrosis; CT; Closed-loop small bowel obstruction; Diagnosis; Reduced bowel wall enhancement.

MeSH terms

  • Abdominal Injuries* / complications
  • Humans
  • Intestinal Obstruction* / diagnostic imaging
  • Intestinal Obstruction* / surgery
  • Intestine, Small / diagnostic imaging
  • Necrosis / diagnostic imaging
  • Necrosis / pathology
  • Reproducibility of Results
  • Retrospective Studies
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods
  • Vascular Diseases* / pathology