Transapical Mitral Valve Replacement: 1-Year Results of the Real-World Tendyne European Experience Registry

JACC Cardiovasc Interv. 2024 Mar 11;17(5):648-661. doi: 10.1016/j.jcin.2023.12.027. Epub 2024 Feb 21.

Abstract

Background: Early studies of the Tendyne transcatheter mitral valve replacement (TMVR) showed promising results in a small selective cohort.

Objectives: The authors present 1-year data from the currently largest commercial, real-world cohort originating from the investigator-initiated TENDER (Tendyne European Experience) registry.

Methods: All patients from the TENDER registry eligible for 1-year follow-up were included. The primary safety endpoint was 1-year cardiovascular mortality. Primary performance endpoint was reduction of mitral regurgitation (MR) up to 1 year.

Results: Among 195 eligible patients undergoing TMVR (median age 77 years [Q1-Q3: 71-81 years], 60% men, median Society of Thoracic Surgeons Predicted Risk of Mortality 5.6% [Q1-Q3: 3.6%-8.9%], 81% in NYHA functional class III or IV, 94% with MR 3+/4+), 31% had "real-world" indications for TMVR (severe mitral annular calcification, prior mitral valve treatment, or others) outside of the instructions for use. The technical success rate was 95%. The cardiovascular mortality rate was 7% at 30 day and 17% at 1 year (all-cause mortality rates were 9% and 29%, respectively). Reintervention or surgery following discharge was 4%, while rates of heart failure hospitalization reduced from 68% in the preceding year to 25% during 1-year follow-up. Durable MR reduction to ≤1+ was achieved in 98% of patients, and at 1 year, 83% were in NYHA functional class I or II. There was no difference in survival and major adverse events between on-label use and "real-world" indications up to 1 year.

Conclusions: This large, real-world, observational registry reports high technical success, durable and complete MR elimination, significant clinical benefits, and a 1-year cardiovascular mortality rate of 17% after Tendyne TMVR. Outcomes were comparable between on-label use and "real-world" indications, offering a safe and efficacious treatment option for patients without alternative treatments. (Tendyne European Experience Registry [TENDER]; NCT04898335).

Keywords: mitral annular calcification; mitral regurgitation; mitral valve; transcatheter mitral valve replacement.

MeSH terms

  • Aged
  • Cardiac Catheterization / methods
  • Female
  • Heart Valve Prosthesis Implantation*
  • Heart Valve Prosthesis* / adverse effects
  • Humans
  • Male
  • Mitral Valve / diagnostic imaging
  • Mitral Valve / surgery
  • Mitral Valve Insufficiency* / diagnostic imaging
  • Mitral Valve Insufficiency* / surgery
  • Registries
  • Treatment Outcome

Associated data

  • ClinicalTrials.gov/NCT04898335