Safety and effectiveness of the novel Myval Octacor transcatheter heart valve in severe, symptomatic aortic valve stenosis - A real-world Indian experience (The OCTACOR India Study)

Cardiovasc Revasc Med. 2024 Jun:63:1-7. doi: 10.1016/j.carrev.2024.01.016. Epub 2024 Jan 28.

Abstract

Purpose: To evaluate the safety and effectiveness of the novel, next-generation Myval Octacor - Transcatheter Heart Valve (THV) in patients with severe, symptomatic, native aortic stenosis (AS).

Methods: This multicenter, real-world observational registry included 123 patients with severe symptomatic AS, across 16 Indian centers who underwent treatment with the novel Myval Octacor THV. Study endpoints included all-cause mortality, all stroke, acute kidney injury (AKI), major vascular complications, moderate or severe paravalvular leakage (PVL) and new permanent pacemaker implantation (PPI) until 30 days follow-up.

Results: Of the 123 patients (average age 70.07 ± 8.33 years), 37.4 % (n = 46) were female and 39.84 % presented with bicuspid valves. The technical success rate of the procedure was 100 % and the device success rate at 30 days was 98.4 %. At 30 days (n = 123) after the procedure, the overall mortality was 1.6 %. AKI occurred in 1.6 % of patients and there was no incidence of stroke, bleeding (types 3 and 4), and major vascular complications. In an analysis of 31 patients whose echocardiographic parameters were available across all timepoints, there were significant improvements in the mean pressure gradient (54.31 ± 18.19 mmHg vs. 10.42 ± 4.24 mmHg; p < 0.0001) and effective orifice area (0.66 ± 0.21 cm2 vs. 1.80 ± 0.44 cm2; p < 0.0001) from baseline to the 30-day follow-up. None of the patients experienced severe PVL, while moderate PVL was observed in two patients (1.6 %).

Conclusions: Early outcomes of the next-generation, novel Myval Octacor THV proved its safety and effectiveness in the treatment of severe AS.

Keywords: Myval Octacor THV; Paravalvular leakage; Symptomatic severe native aortic valve stenosis; Transcatheter aortic valve implantation.

Publication types

  • Multicenter Study
  • Observational Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve Stenosis* / diagnostic imaging
  • Aortic Valve Stenosis* / mortality
  • Aortic Valve Stenosis* / physiopathology
  • Aortic Valve Stenosis* / surgery
  • Aortic Valve* / diagnostic imaging
  • Aortic Valve* / physiopathology
  • Aortic Valve* / surgery
  • Female
  • Heart Valve Prosthesis*
  • Hemodynamics
  • Humans
  • India
  • Male
  • Middle Aged
  • Postoperative Complications
  • Prosthesis Design*
  • Recovery of Function
  • Registries*
  • Retrospective Studies
  • Risk Factors
  • Severity of Illness Index*
  • Time Factors
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Transcatheter Aortic Valve Replacement* / instrumentation
  • Transcatheter Aortic Valve Replacement* / mortality
  • Treatment Outcome