Effectiveness and complication rates of high intensity focused ultrasound treatment for abdominal wall endometriosis: A systematic review

Eur J Obstet Gynecol Reprod Biol. 2024 Jun:297:15-23. doi: 10.1016/j.ejogrb.2024.03.029. Epub 2024 Mar 26.

Abstract

In this review, a systematic literature search on the effectiveness and complication rates of ultrasound-guided and magnetic resonance-guided high-intensity focused ultrasound (USg-/MRgHIFU) for abdominal wall endometriosis (AWE) was conducted in six databases in May/June 2023. Original articles of (non)randomized trials, cohort studies, case-control studies and case series published in peer-reviewed journals were included. Of the included studies the level of evidence (LoE) and methodological quality using the ROBINS-I and IHE-QAT was assessed. Primary outcomes were non-perfused volume ratio (NPV%), lesion size, pain scores, side effects and complication rates according to Society of Interventional Radiology (SIR) guidelines. Secondary outcomes were recurrence and re-intervention rates. Seven cohort studies (one of good methodological quality) (LoE 3) on USgHIFU were included (n = 212, AWE lesions = 240-245). Six months after USgHIFU treatment, pain scores were reduced with 3.3-5.2 points (baseline: 5.1-6.8, n = 135). Self-limiting side effects were pain (85.7 % (114/133)) and swelling (34.6 % (46/133)) in the treatment area. Complications occurred in 17.7 % (32/181), all of which were minor. Recurrence occurred in 12.8 % (11/86). Three of these seven cohort studies compared USgHIFU (n = 61) with surgical excision (n = 74). Pooled results showed no significant differences in pain scores, complications (resp. 26.3 % (10/38) vs. 32.6 % (15/46) (p = 0.53)) and recurrences (resp. 4.9 % (3/61) vs. 5.4 % (4/74) (p = 0.90)). This systematic review suggests that HIFU is an effective and safe treatment option for AWE. USgHIFU treatment led to reduced pain scores and lesion size, was free of major complications and had a pooled recurrence rate of 12.8 %. Compared to surgical excision pooled results showed no significant differences in pain scores, complications and recurrences after USgHIFU. However, many of the included studies had limitations in their methodological quality and therefore the results should be interpreted with caution. Well-structured high-quality randomized controlled trials comparing HIFU to standard care should be conducted to provide more conclusive evidence.

Keywords: Abdominal wall endometriosis; Focused ultrasound surgery; High intensity focused ultrasound; Systematic review.

Publication types

  • Systematic Review
  • Review

MeSH terms

  • Abdominal Wall* / surgery
  • Endometriosis* / surgery
  • Endometriosis* / therapy
  • Female
  • High-Intensity Focused Ultrasound Ablation* / adverse effects
  • High-Intensity Focused Ultrasound Ablation* / methods
  • Humans
  • Treatment Outcome
  • Ultrasonography, Interventional