Background: Pulsed-field ablation (PFA) has shown promising data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI), with similar long-term outcomes compared to radiofrequency ablation (RFA) and cryoballoon ablation (CBA) in patients with paroxysmal atrial fibrillation (AF).
Objective: The purpose of this study was to compare the procedural and long-term outcomes in patients with persistent AF undergoing PVI using PFA, CBA, or RFA.
Methods: Consecutive patients with persistent AF undergoing first PVI with PFA, CBA, or RFA were included. Patients underwent 7-day Holter electrocardiography at 3, 6, and 12 months postablation. The primary outcome was recurrence of any atrial arrhythmia after a 90-day blanking period. Safety outcomes included the composite of in-hospital major adverse events.
Results: A total of 533 patients with persistent AF underwent PVI using PFA (n = 214, 39%), CBA (n = 190, 36%), or RFA (n = 129, 24%). Procedures with PFA guided by fluoroscopy were shorter than those with CBA (median 60 minutes; interquartile range [IQR] 53-80 minutes vs 84 minutes; IQR 68-101 minutes; P ≤ .001), and procedures with PFA in combination with 3-dimensional electroanatomic mapping were shorter than those with RFA (median 101 minutes; IQR 85-126 minutes vs 171 minutes; IQR 141-204 minutes; P < .001). Acute safety events occurred in 2.3%, 2.6%, and 0.8% in the PFA, CBA, and RFA groups, respectively (P = .545). The 1-year confounder-adjusted estimate for freedom from atrial arrhythmias was 62.1% for CBA, 55.3% for PFA, and 48.3% for RFA (CBA vs PFA: P = .79; CBA vs RFA: P = .009; PFA vs RFA: P = .010).
Conclusion: In patients with persistent AF undergoing first PVI, 1-year confounder-adjusted outcomes are better with PFA and CBA than with RFA.
Keywords: Cryoballoon ablation; Persistent atrial fibrillation; Pulmonary vein isolation; Pulsed-field ablation; Radiofrequency ablation.
Copyright © 2024 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.