Feasibility of comprehensive genomic profiling using endoscopic ultrasound-guided tissue acquisition with a 22-gauge Franseen needle

DEN Open. 2024 Apr 15;4(1):e365. doi: 10.1002/deo2.365. eCollection 2024 Apr.

Abstract

Aim: Comprehensive genomic profiling (CGP) test for solid tumors is now increasingly utilized in clinical practice, especially in pancreatobiliary cancer, and specimens obtained by endoscopic ultrasound-guided tissue acquisition (EUS-TA) are often submitted for tissue-based CGP test. In this study, we evaluated the feasibility of EUS-TA using a 22-gauge Franseen needle for the CGP test.

Methods: Consecutive patients with solid tumors who underwent EUS-TA using a 22-gauge Franseen needle, and whose tissue samples were pre-checked for suitability for CGP test, were included in this single-center, retrospective analysis. The success rates of appropriate sample collection for CGP evaluated by pathologists (1st quality control) and CGP test (2nd quality control) were evaluated. In addition, The EUS-TA slides were evaluated for the tissue area and tumor area content, using the image software.

Results: A total of 50 cases, with 78% of pancreatic cancer, were included in the analysis. A median of 3 passes of EUS-TA were performed with an adverse event rate of 4%. The success rates for 1st and 2nd quality control for CGP tests were 86% and 76%, respectively. The image analyses suggested EUS-TA specimen did not always fulfill CGP test criteria, with 18% of tissue area ≥16 mm2 and 38% of tumor area content ≥20%, even in cases with successful CGP tests. The suction method yielded a significantly larger amount of DNA but without a significant difference in the multivariate analysis.

Conclusions: The present study demonstrated the feasibility of EUS-TA using a 22-gauge Franseen needle for CGP test.

Keywords: Franseen needle; comprehensive genomic profiling; endoscopic ultrasound‐guided fine needle aspiration; image analysis; pancreatobiliary cancer.