Updated 2022 ACC/AHA Guideline Improves Concordance Between TTE and CT in Monitoring Marfan Snydrome and Related Disorders, but Relevant Measurement Differences Remain Frequent

Glob Heart. 2024 May 8:23:28. doi: 10.5334/gh.1322. eCollection 2024.

Abstract

Background: Patients diagnosed with Marfan syndrome or a related syndrome require frequent aorta monitoring using imaging techniques like transthoracic echocardiography (TTE) and computed tomography (CT). Accurate aortic measurement is crucial, as even slight enlargement (>2 mm) often necessitates surgical intervention. The 2022 ACC/AHA guideline for Aortic Disease Diagnosis and Management includes updated imaging recommendations. We aimed to compare these with the 2010 guideline.

Methods: This retrospective study involved 137 patients with Marfan syndrome or a related disorder, undergoing TTE and ECG-triggered CT. Aortic diameter measurements were taken based on the old 2010 guideline (TTE: inner edge to inner edge, CT: external diameter) and the new 2022 guideline (TTE: leading edge to leading edge, CT: internal diameter). Bland-Altman plots compared measurement differences.

Results: Using the 2022 guideline significantly reduced differences outside the clinical agreement limit from 49% to 26% for the aortic sinus and from 41% to 29% for the ascending aorta. Mean differences were -0.30 mm for the aortic sinus and +1.12 mm for the ascending aorta using the 2022 guideline, compared to -2.66 mm and +1.21 mm using the 2010 guideline.

Conclusion: This study demonstrates for the first time that the 2022 ACC/AHA guideline improves concordance between ECG-triggered CT and TTE measurements in Marfan syndrome patients, crucial for preventing life-threatening aortic complications. However, the frequency of differences >2 mm remains high.

Clinical relevance/application: Accurate aortic diameter measurement is vital for patients at risk of fatal aortic complications. While the 2022 guideline enhances concordance between imaging modalities, frequent differences >2 mm persist, potentially impacting decisions on aortic repair. The risk of repeat radiation exposure from ECG-triggered CT, considered the 'gold standard', continues to be justified.

Keywords: Computed tomography; Marfan syndrome and related disorders; Monitoring aortic enlargement; transthoracic echocardiography.

MeSH terms

  • Adolescent
  • Adult
  • Aorta / diagnostic imaging
  • Echocardiography* / methods
  • Female
  • Humans
  • Male
  • Marfan Syndrome* / diagnosis
  • Marfan Syndrome* / diagnostic imaging
  • Middle Aged
  • Practice Guidelines as Topic
  • Retrospective Studies
  • Tomography, X-Ray Computed* / methods
  • United States / epidemiology
  • Young Adult