Reliability and reference values for diaphragmatic excursion, thickness, and thickening fraction and quadriceps femoris muscle thickness in full-term newborns evaluated by ultrasound

Eur J Pediatr. 2024 Aug;183(8):3453-3460. doi: 10.1007/s00431-024-05608-1. Epub 2024 May 21.

Abstract

To determine the diaphragm thickness, thickening fraction, and excursion and thickness of the quadriceps femoris muscle in full-term newborns and to evaluate the intra- and interrater reliability of these measurements. This was a prospective, observational clinical study including full-term newborns born within the first 48 h after birth. Serial measurements of the thickness, thickening fraction, and mobility of the diaphragm muscles and the thickness of the quadriceps muscle were obtained using ultrasound images. A total of 69 newborns with a mean gestational age of 39 weeks were included. The following measurements were obtained and are expressed as the mean (standard deviation): inspiratory diaphragm thickness, 0.19 cm (0.04); expiratory diaphragm thickness, 0.16 cm (0.04); diaphragm thickness fraction, 16.70 cm (10.27); diaphragmatic excursion, 0.68 cm (0.22); and quadriceps thickness, 0.99 cm (0.14). Intrarater reliability was assessed using intraclass correlation coefficients (ICCs). Excellent intrarater agreement was observed for the two groups of operators (ICC > 0.86, p < 0.001) for all measurements except for the diaphragm thickening fraction, which showed good agreement for both operator groups (ICC = 0.70, p < 0.001). Regarding interrater reliability, moderate agreement between the raters was observed in the means of all measures (ICC > 0.49, p < 0.001), except for the diaphragm thickening fraction, which showed poor agreement. Conclusion: Good intrarater and moderate interrater reliability were achieved in ultrasound evaluations of the thickness and mobility of the diaphragm and quadriceps femoris muscles in full-term newborns, demonstrating the feasibility of this technique for clinical use. This pioneering study offers reference values for these muscles in a single study, allowing comparisons between different clinical conditions. What is Known: • Ultrasound is a highly reliable tool for muscle assessment that can be used to assess muscular atrophy in critically ill patients. • Muscle atrophy worsens the patient's condition and has been associated with worse outcomes. What is New: • To our knowledge, this is the first study to jointly evaluate the diaphragm and quadriceps muscle thickness and evaluate the reliability of all measurements. • Our study presents reference values for both muscles, enabling comparisons between different clinical conditions.

Keywords: Diaphragm thickening fraction; Diaphragm thickness; Full-term newborn; Quadriceps thickness; Ultrasound.

Publication types

  • Observational Study

MeSH terms

  • Diaphragm* / diagnostic imaging
  • Female
  • Gestational Age
  • Humans
  • Infant, Newborn
  • Male
  • Observer Variation
  • Prospective Studies
  • Quadriceps Muscle* / anatomy & histology
  • Quadriceps Muscle* / diagnostic imaging
  • Reference Values
  • Reproducibility of Results
  • Ultrasonography* / methods