Crack Resistance of Lightly Reinforced Concrete Structures

Materials (Basel). 2024 May 8;17(10):2197. doi: 10.3390/ma17102197.

Abstract

The crack resistance of concrete structures with low reinforcement ratios requires a broader examination. It is particularly important in the case of foundations working in changing subsoil conditions. Unfavorable phenomena occurring in the subsoil (e.g., ground subsidence, landslips, non-uniform settlement) can lead to unexpected cracking. Therefore, it is necessary to check the effectiveness of the low reinforcement provided. As there are limited studies on lightly reinforced concrete structures, we performed our own experimental investigation and numerical calculations. In the beams analyzed, the reinforcement ratio varied from 0.05% to 0.20%. It was found that crack resistance in concrete members depends on the reinforcement ratio and steel bar distribution. A comprehensive method was proposed for estimating the crack resistance of lightly reinforced concrete members in which both the reinforcement ratio and the reinforcement dispersion ratio were taken into account. Furthermore, the method considered the size effect and the fracture properties of concrete. The proposed method provides the basis for extrapolation of the test results obtained for small elements and conclusions for members with large cross-sections, such as foundations, which frequently use lightly reinforced concrete.

Keywords: concrete structures; crack resistance; flexural concrete members; fracture parameters of concrete; reinforcement ratio; scale effect.