Predicting Stroke for Pediatric Patients Supported With Ventricular Assist Devices: A Pedimacs Report

Ann Thorac Surg. 2024 Oct;118(4):889-897. doi: 10.1016/j.athoracsur.2024.05.009. Epub 2024 May 25.

Abstract

Background: The Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) provides detailed understanding on pediatric patients supported with ventricular assist devices (VADs). We sought to identify important variables affecting the incidence of stroke in pediatric VADs.

Methods: Between 2012 and 2022, 1463 devices in 1219 patients were reported to Pedimacs from 40 centers in patients aged <19 years at their first VAD implantation. Multiphase parametric hazard modeling was used to identify risk factors for stroke among all device types.

Results: Of the 1219 patients, the most common devices were implantable continuous (472 [39%]), followed by paracorporeal pulsatile (342 [28%]), and paracorporeal continuous (327 [27%]). Overall freedom from stroke at 6 months was higher in the recent era (2012-2016; 80.2% [95% CI, 77.1%-82.9%] vs 2017-2023; 87.9% [95% CI, 86.2%-89.4%], P = .009). Implantable continuous VADs had the highest freedom from stroke at 3 months (92.7%; 95% CI, 91.1%-93.9%) and 6 months (91.1%; 95% CI, 89.3%-92.6%), followed by paracorporeal pulsatile (87.0% [95% CI, 84.8%-88.9%] and 82.8% [95% CI, 79.8%-85.5%], respectively), and paracorporeal continuous (76.0% [95% CI, 71.8%-79.5%] and 69.5% [95% CI, 63.4%-74.8%], respectively) VADs. Parametric modeling identified risk factors for stoke early after implant and later. Overall, and particularly for paracorporeal pulsatile devices, early stroke risk has decreased in the most recent era (hazard ratio, 5.01). Among implantable continuous devices, cardiogenic shock was the major risk factor. For patients <10 kg, early hazard was only seen in the previous era. For congenital patients, early hazard was seen in nonimplantable device use and use of extracorporeal membrane oxygenation.

Conclusions: The overall stroke rate has decreased from 20% to 15% at 6 months, with particular improvement among paracorporeal pulsatile devices. Risk factor analyses offer insights for identification of higher stroke risk subsets and further management refinements.

Publication types

  • Multicenter Study

MeSH terms

  • Adolescent
  • Child
  • Child, Preschool
  • Female
  • Heart Failure / therapy
  • Heart-Assist Devices* / adverse effects
  • Humans
  • Incidence
  • Infant
  • Male
  • Registries*
  • Retrospective Studies
  • Risk Assessment
  • Risk Factors
  • Stroke* / epidemiology
  • Stroke* / etiology
  • United States / epidemiology