Background: To assess contrast-enhanced mammography (CEM) in the management of BI-RADS3 breast architectural distortions (AD) in digital breast tomosynthesis (DBT).
Methods: We retrospectively reviewed 328 women with 332 ADs detected on DBT between 2017 and 2021 and selected those classified as BI-RADS3 receiving CEM as problem-solving. In CEM recombined images, we evaluated AD's contrast enhancement (CE) according to its presence/absence, type, and size. AD with enhancement underwent imaging-guided biopsy while AD without enhancement follow-up or biopsy if detected in high/intermediate-risk women.
Results: AD with enhancement were 174 (52.4%): 72 (41.4%) were malignant lesions, 102 (59.6%) false positive results: 28 (16%) B3 lesions, and 74 (42.5%) benign lesions. AD without enhancement were 158 (47.6%): 26 (16.5%) were subjected to biopsy (1 malignant and 25 benign) while the other 132 cases were sent to imaging follow-up, still negative after two years. CEM's sensitivity, specificity, positive (PPV) and negative predictive values (NPV), and accuracy were 98.63%, 60.62%, 41.38%, 99.37%, and 68.98%. The AUC determined by ROC was 0.796 (95% CI, 0.749-0.844).
Conclusion: CEM has high sensitivity and NPV in evaluating BI-RADS3 AD and can be a complementary tool in assessing AD, avoiding unnecessary biopsies without compromising cancer detection.
Keywords: Breast cancer; CEM; Distortions.
© 2024. The Author(s), under exclusive licence to The Japanese Breast Cancer Society.