Changes in Peak Inspiratory Flow After Acute Bronchodilation: An Observational Study of Patients with Stable Chronic Obstructive Pulmonary Disease

J Aerosol Med Pulm Drug Deliv. 2024 Aug;37(4):171-179. doi: 10.1089/jamp.2023.0045. Epub 2024 May 29.

Abstract

Introduction: Identifying factors influencing peak inspiratory flow (PIF) is essential for aerosol drug delivery in stable patients with chronic obstructive pulmonary disease. While a minimum PIF for dry powder inhalers (DPIs) is established, acute bronchodilator (BD) effects on PIF remain unknown. Materials and Methods: An inspiratory flow meter (In-Check™ DIAL) was used to measure PIF in stable patients during a 24-week observational cross-sectional study. Additionally, bronchodilator responsiveness (BDR) was determined using the In-Check DIAL device and spirometry. Patients received four puffs of albuterol, and pre- and post-BD PIF, forced expiratory volume in one second (FEV1), and forced vital capacity were measured. Sixty-three patients completed acute BDR data collection from July 31, 2019, to November 9, 2021. Primary endpoints were pre- and post-BD spirometry and PIF. Statistical analyses included PIF correlations with FEV1. BD change was assessed according to inhaler resistance and sex (subgroup analysis). Results: Median patient age was 64.8 years, 85.7% were non-Hispanic White, and 57.1% were female. The median increase in absolute PIF (In-Check DIAL) was 5.0 L/min, and the % PIF change was 8.9%. With albuterol, 57.1% experienced a PIF BD change >5.0%, whereas 49.2% experienced a change >10.0%. Similarly, 55.6% experienced an FEV1 BD change >5.0% and 28.6% had a >10.0% FEV1 BD change with albuterol. PIF was weakly correlated with FEV1 BD change (absolute; % PIF; r = 0.28 [p = 0.02]; r = 0.21 [p = 0.11]). Pre- and post-BD median PIF were 75.5 and 83.5 L/min for low-to-medium-resistance DPI and 45.0 and 52.0 L/min for high-resistance, respectively. The median increases in pre- and post-BD PIF were 9.0 L/min in males and 4.5 L/min in females. In contrast to when using the In-Check DIAL device, we observed no consistent bronchodilatory effects on PIF measured by spirometry. Conclusions: Using the In-Check DIAL device, ∼50% of patients experienced >10% PIF increase after acute BD, potentially enhancing medication lung deposition. Further research is required to understand PIF's impact on medication delivery. ClinicalTrials.gov Identifier: NCT04168775.

Keywords: In-Check DIAL; bronchodilator; bronchodilator responsiveness; chronic obstructive pulmonary disease; dry powder inhaler; peak inspiratory flow.

Publication types

  • Observational Study

MeSH terms

  • Administration, Inhalation
  • Aerosols
  • Aged
  • Albuterol* / administration & dosage
  • Bronchodilator Agents* / administration & dosage
  • Cross-Sectional Studies
  • Dry Powder Inhalers*
  • Female
  • Forced Expiratory Volume
  • Humans
  • Inhalation / physiology
  • Male
  • Middle Aged
  • Pulmonary Disease, Chronic Obstructive* / drug therapy
  • Pulmonary Disease, Chronic Obstructive* / physiopathology
  • Spirometry*
  • Vital Capacity

Substances

  • Bronchodilator Agents
  • Albuterol
  • Aerosols

Associated data

  • ClinicalTrials.gov/NCT04168775