Robotic Magnetic Sphincter Augmentation Device Removal

Innovations (Phila). 2024 May-Jun;19(3):306-309. doi: 10.1177/15569845241254124. Epub 2024 Jun 3.

Abstract

Although most patients with reflux can be managed with medical therapy, some require surgical intervention to manage their disease. Newer technologies, such as magnetic sphincter augmentation (MSA), have been promoted as the replacement of fundoplication. However, as time has elapsed, our institution noticed the need for the removal of MSA devices. Although a few reports have described MSA device removals, we provide a deeper explanation of how to perform a robotic device removal. Our article describes the technical steps and includes a video to demonstrate how to complete the surgery robotically.

Keywords: GERD; LINX; magnetic sphincter augmentation; reflux; robot.

MeSH terms

  • Device Removal* / instrumentation
  • Device Removal* / methods
  • Esophageal Sphincter, Lower / surgery
  • Fundoplication / instrumentation
  • Fundoplication / methods
  • Gastroesophageal Reflux / surgery
  • Humans
  • Robotic Surgical Procedures* / instrumentation
  • Robotic Surgical Procedures* / methods