Combined Endovascular and Endoscopic Management of a Secondary Aortoesophageal Fistula after Open Surgical Aortic Repair in a Giant Descending Thoracic Aortic Pseudoaneurysm: Case Report and Review of Literature

J Pers Med. 2024 Jun 11;14(6):625. doi: 10.3390/jpm14060625.

Abstract

Secondary aortoesophageal fistula (AEF) is defined as a communication between the aorta and the esophagus, occurring after aortic disease treatment or esophageal procedures, associating very high mortality rates with treatment and being fatal without it. Several treatment strategies have been described in the literature, combining open surgery or endovascular aortic repair with surgical or endoscopic management of the esophageal lesion. We present the case of a 53-year-old patient with a history of open aortic surgery for a giant descending thoracic aortic pseudoaneurysm complicated with secondary AEF, successfully managed using emergency transiliac TEVAR (thoracic endovascular aortic repair), extensive antibiotic therapy associated with nutritional replenishment, and rehabilitation therapy. Novel endovascular and endoscopic devices have been developed, offering less invasive treatment strategies with improved outcomes, especially for high risk surgical patients. This case highlights the importance of a multidisciplinary approach to personalized medicine to manage such complex situations.

Keywords: TEVAR; aortic repair; esophageal stent; secondary aortoesophageal fistula.

Publication types

  • Review

Grants and funding

The publication of this paper was supported by the University of Medicine and Pharmacy Carol Davila through the institutional program Publish not Perish.