Optical coherence tomography predictors of clinical outcomes after stent implantation: the ILUMIEN IV trial

Eur Heart J. 2024 Nov 14;45(43):4630-4643. doi: 10.1093/eurheartj/ehae521.

Abstract

Background and aims: Observational registries have suggested that optical coherence tomography (OCT) imaging-derived parameters may predict adverse events after drug-eluting stent (DES) implantation. The present analysis sought to determine the OCT predictors of clinical outcomes from the large-scale ILUMIEN IV trial.

Methods: ILUMIEN IV was a prospective, single-blind trial of 2487 patients with diabetes or high-risk lesions randomized to OCT-guided versus angiography-guided DES implantation. All patients underwent final OCT imaging (blinded in the angiography-guided arm). From more than 20 candidates, the independent OCT predictors of 2-year target lesion failure (TLF; the primary endpoint), cardiac death or target-vessel myocardial infarction (TV-MI), ischaemia-driven target lesion revascularization (ID-TLR), and stent thrombosis were analysed by multivariable Cox proportional hazard regression in single treated lesions.

Results: A total of 2128 patients had a single treated lesion with core laboratory-analysed final OCT. The 2-year Kaplan-Meier rates of TLF, cardiac death or TV-MI, ID-TLR, and stent thrombosis were 6.3% (n = 130), 3.3% (n = 68), 4.3% (n = 87), and 0.9% (n = 18), respectively. The independent predictors of 2-year TLF were a smaller minimal stent area (per 1 mm2 increase: hazard ratio 0.76, 95% confidence interval 0.68-0.89, P < .0001) and proximal edge dissection (hazard ratio 1.77, 95% confidence interval 1.20-2.62, P = .004). The independent predictors of cardiac death or TV-MI were smaller minimal stent area and longer stent length; of ID-TLR were smaller intra-stent flow area and proximal edge dissection; and of stent thrombosis was smaller minimal stent expansion.

Conclusions: In the ILUMIEN IV trial, the most important OCT-derived post-DES predictors of both safety and effectiveness outcomes were parameters related to stent area, expansion and flow, proximal edge dissection, and stent length.

Keywords: Optical coherence tomography; Percutaneous coronary intervention; Prognosis; Stent.

Publication types

  • Randomized Controlled Trial
  • Multicenter Study

MeSH terms

  • Aged
  • Coronary Angiography
  • Coronary Artery Disease / diagnostic imaging
  • Coronary Artery Disease / surgery
  • Coronary Artery Disease / therapy
  • Drug-Eluting Stents*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Myocardial Infarction / epidemiology
  • Percutaneous Coronary Intervention / adverse effects
  • Percutaneous Coronary Intervention / methods
  • Prospective Studies
  • Single-Blind Method
  • Tomography, Optical Coherence* / methods
  • Treatment Outcome

Grants and funding