Ion exchange chromatography-tandem mass spectrometry (IEC-MS/MS) has recently become the preferred method for detecting ionic substances in tea. In this study, an IEC-MS/MS method was developed for the rapid determination of chlorate and perchlorate residues in tea samples. The optimal sample extraction process, pretreatment column, and chromatographic and mass spectrometric conditions were systematically investigated. In the optimal process, the tea samples were ultrasonically extracted with methanol-water (13∶7, v/v), and a PRiME HLB SPE column was used to purify the sample extract. An AceChrom Hybri-A IEC column (150 mm×2.1 mm, 5.0 μm) was used for separation, and 100 mmol/L ammonium acetate-acetonitrile (40∶60, v/v) was used as the mobile phase for isocratic elution. The flow rate was 0.3 mL/min, the column temperature was 40 ℃, and the injection volume was 5.0 μL. The mass spectrometric data were collected in negative electrospray ionization mode combined with multiple reaction monitoring (MRM) mode to achieve the rapid and accurate separation and qualitative analysis of the desired chemical components. Quantification was performed using the internal standard (IS) method. The measurement results showed a good linear relationship when the mass concentrations of chlorate and perchlorate were between 2.00-200 and 1.00-100 μg/L, respectively, with correlation coefficients (r2) greater than 0.9990. The average recoveries of chlorate and perchlorate at three spiked levels of low, medium, and high ranged from 88.54% to 97.25% with relative standard deviations (RSDs, n=7) of 3.2%-5.2%. The limits of detection for chlorate and perchlorate were 12.0 and 8.0 μg/kg, respectively, while the limits of quantification were 40.0 and 26.6 μg/kg, respectively. The results of tests conducted to assess the linearity, specificity, accuracy, precision, and applicability of the method to the analysis of chlorate and perchlorate in 15 tea samples collected from a local market demonstrated its validity for the routine analysis of tea samples. The proposed method is simple, rapid, sensitive, and accurate, and can meet requirements for the rapid screening and quantitative analysis of residual trace chlorate and perchlorate in large quantities of tea samples.
目前,氯酸盐和高氯酸盐作为新型持久性环境污染物受到了广泛关注。茶树在我国有大面积种植,而在受高氯酸盐污染的土壤中,其含有的氯酸盐和高氯酸盐可在茶树中富集,鉴于氯酸盐和高氯酸盐对人体具有的潜在健康风险,因此亟需建立一种茶叶中氯酸盐和高氯酸盐残留量的快速检测方法。本文建立了茶叶中氯酸盐和高氯酸盐残留量的离子交换色谱-串联质谱检测方法。本研究优选Oasis PRiME HLB SPE柱对样品提取液进行净化,使用AceChrom Hybri-A (150 mm×2.1 mm, 5.0 μm)作为离子交换色谱柱,以100 mmol/L乙酸铵-乙腈(40∶60, v/v)作为流动相,在电喷雾负离子和MRM模式下,对目标物实现快速、准确的定性分析,并采用内标法定量。研究结果表明:当氯酸盐与高氯酸盐分别在2.00~200 μg/L和1.00~100 μg/L范围内时,方法的线性关系良好(r2>0.9990);在低、中、高3个加标水平下,氯酸盐和高氯酸盐平均回收率为88.54%~97.25%,方法的检出限分别为12.0 μg/kg和8.0 μg/kg,方法的定量限分别为40.0 μg/kg和26.6 μg/kg。该方法简单、快速、灵敏、准确,能够满足大批量茶叶样品中氯酸盐和高氯酸盐的快速筛查与定量分析。
Keywords: chlorate; ion exchange chromatography-tandem mass spectrometry (IEC-MS/MS); perchlorate; tea.