Amplitude-Integrated Electroencephalography: A Readily Available Tool for Neonatologists

Cureus. 2024 Aug 16;16(8):e67018. doi: 10.7759/cureus.67018. eCollection 2024 Aug.

Abstract

Hypoxic-ischemic encephalopathy (HIE) is a common condition occurring at birth, impairing central nervous system function. Therapeutic hypothermia is beneficial for suspected HIE as it reduces mortality and disability in survivors but not for other types of encephalopathy (e.g., metabolic). Amplitude-integrated electroencephalography (aEEG) complements limited resource Neonatal Intensive Care Units as a screening tool that can provide information regarding the degree of encephalopathy and electrographic seizures. Patients with HIE are at increased risk for seizures, which are subclinical in half of the cases. The aEEG emphasizes electroencephalographic amplitude differences, whereas continuous video electroencephalography (cEEG) provides a high-resolution picture of cerebral electrical activity, making it the most accurate method for detecting subclinical seizures. Still, its interpretation demands extensive training beyond the scope of neonatologists. Any infant in whom aEEG is suspicious for seizures should undergo cEEG to confirm the findings because even very low-amplitude artifacts might be misdiagnosed as seizures. We report a case and review the utility of aEEG in detecting subclinical seizures in neonates with HIE during therapeutic hypothermia while cEEG is not available.

Keywords: amplitude-integrated electroencephalography (aeeg); hypoxic-ischemic encephalopathy (hie); neonate; seizures; therapeutic hypothermia.

Publication types

  • Case Reports