Stent Underexpansion Is an Underestimated Cause of Intrastent Restenosis: Insights From RESTO Registry

J Am Heart Assoc. 2024 Nov 5;13(21):e036065. doi: 10.1161/JAHA.124.036065. Epub 2024 Oct 25.

Abstract

Background: Despite improvement in devices, in-stent restenosis remains a frequent and challenging complication of percutaneous coronary interventions.

Methods and results: The RESTO (Morphological Parameters of In-Stent Restenosis Assessed and Identified by OCT [Optical Coherence Tomography]; study NCT04268875) was a prospective multicenter registry including patients presenting with coronary syndromes related to in-stent restenosis. All patients underwent preintervention OCT analysis, which led to analysis of in-stent restenosis phenotype, number of strut layers, and presence of stent underexpansion. The primary end point was the in-stent restenosis type according to the OCT morphological classification. The 1-year incidence of target vessel failure (a composite of death from cardiac causes, target-vessel myocardial infarction, or ischemia-driven target-vessel revascularization) was assessed. The study included 297 patients. The culprit stent was a drug-eluting stent in 74.2% of cases. OCT analysis revealed the presence of neoatherosclerosis in 57% (52% calcified), neointimal hyperplasia in 43% (58% homogeneous), stent underexpansion (minimal stent area <4.5 mm2) in 43%, and multiple stent layers in 30%. The prepercutaneous coronary intervention OCT analysis modified the operator's strategy for management in 30% of cases. Treatment involved drug-eluting stent implantation in 61.6% and drug-eluting balloon angioplasty in 36.1% of cases with only 63.2% optimal results. The 1-year target vessel failure incidence was 11% (95% CI, 9%-13%). Residual postpercutaneous coronary intervention stent underexpansion was associated with significantly higher target vessel failure incidence (19% [95% CI, 14%-24%] versus 7% [95% CI, 5-9], P=0.01).

Conclusions: OCT identified neoatherosclerosis and neointimal hyperplasia in comparable proportions. Stent underexpansion was frequent and favored subsequent adverse clinical outcomes.

Keywords: in‐stent restenosis; optical coherence tomography; underexpansion.

Publication types

  • Multicenter Study
  • Observational Study

MeSH terms

  • Aged
  • Coronary Artery Disease / diagnostic imaging
  • Coronary Artery Disease / surgery
  • Coronary Artery Disease / therapy
  • Coronary Restenosis* / diagnostic imaging
  • Coronary Restenosis* / epidemiology
  • Coronary Restenosis* / etiology
  • Coronary Vessels / diagnostic imaging
  • Coronary Vessels / pathology
  • Drug-Eluting Stents* / adverse effects
  • Female
  • Humans
  • Incidence
  • Male
  • Middle Aged
  • Neointima
  • Percutaneous Coronary Intervention* / adverse effects
  • Percutaneous Coronary Intervention* / instrumentation
  • Prospective Studies
  • Registries*
  • Risk Factors
  • Time Factors
  • Tomography, Optical Coherence*
  • Treatment Outcome