Value of P-wave Parameters in Predicting Outcomes of Repeat Catheter Ablation for Paroxysmal Atrial Fibrillation

Pacing Clin Electrophysiol. 2024 Dec 24. doi: 10.1111/pace.15128. Online ahead of print.

Abstract

Background: Pulmonary vein isolation (PVI) has been established as an effective management option for symptomatic paroxysmal atrial fibrillation (PAF). We aimed to explore the role of P-wave parameters in a 12-lead electrocardiogram (ECG) in predicting the success of repeat PAF ablation.

Methods: We enrolled consecutive patients who underwent a second AF ablation procedure for PAF in a UK tertiary center after an index ablation conducted between 2018 and 2019 and a repeat ablation up to 2021. A digital 12-lead ECG was recorded with a 1-50-Hz bandpass filter applied. P-wave duration (PWD), P-wave voltage (PWV), P-wave dispersion (PWDisp), and P-wave terminal force in V1 (PTFV1) were measured before and after the procedure. Changes were correlated with the 12-month clinical outcome. Procedural success was freedom from ECG-documented AF up to 12 months following ablation.

Results: Study criteria were satisfied by 72 patients, of which 43 (60%) had successful repeat PVI at 12 months. The mean age is 65, and 47 (65%) were males. The demographics were comparable between both study arms. PWD decreased after successful repeat ablations (136.7 to 124.6 ms, p = 0.01) and failed repeat ablations (135.4 to 125.3 ms, p = 0.009) without a significant change between both arms. PMV and PWDisp did not change significantly after both study arms. PTFV1 significantly decreased after successful repeat ablations (-3.1 to -4.4 mm.s, p = 0.005) without a significant change after failed ablations (-2.9 to -2.7 mm.s, p = 0.42). Changes were statistically significant between both arms (p = 0.004).

Conclusion: PTFV1 reduction following the second AF ablation was correlated with successful repeat AF ablation at 12 months.

Keywords: PTFV1; P‐waves; atrial fibrillation; repeat ablation.