The clinical application of adipofascial turnover flaps for coverage of severe burn wounds on the digits

Ann Burns Fire Disasters. 2024 Dec 31;37(4):323-329. eCollection 2024 Dec.

Abstract

This article presents particular occupational burn injuries resulting in a complex defect of the digits. Nine patients with exposed bone or tendon wounds on the digits were successfully treated using the pedicle adipofascial turnover flap overlaid with skin grafts. Electrical and high-temperature contact burns resulted in five and four severe cases, respectively. Flaps were harvested from the adjacent dorsal area of the injured digit and the dimension was 2 to 4 mm wider than the defect base on their reliable blood supply. It was suggested that the advantages of adipofascial turnover flaps include a simple, one-stage procedure and minimal donor site deformity.

Cette article se penche sur des accidents de travail responsables de pertes de substance digitales complexes. Neuf patients avec des expositions osseuses ou des lésions tendineuses digitales ont été traités avec succès par des lambeaux adipo- fasciaux de rotation recouverts d’une greffe de peau. Cinq d’entre eux avaient subi une électrisation et quatre une brûlure par contact. Les lambeaux étaient pris sur la face dorsale adjacente, choisis sur la qualité de leur vascularisation, et mesuraient 2 à 4 mm de plus que la surface à couvrir. Cette technique a pour avantages une reconstruction en 1 temps et une conséquence minime pour le site donneur.

Keywords: adipofascial turnover flap; digits; electrical injury; thermal burns.

Publication types

  • Case Reports