Central venous pressure as a method of optimising atrio-ventricular delay after cardiac surgery

PLoS One. 2025 Jan 17;20(1):e0310905. doi: 10.1371/journal.pone.0310905. eCollection 2025.

Abstract

Introduction: Haemodynamic atrioventricular delay (AVD) optimisation has primarily focussed on signals that are not easy to acquire from a pacing system itself, such as invasive left ventricular catheterisation or arterial blood pressure (ABP). In this study, standard clinical central venous pressure (CVP) signals are tested as a potential alternative.

Methods: Sixteen patients with a temporary pacemaker after cardiac surgery were studied. AV delay optimisation was performed by alternating between a reference AVD of 120ms and tested settings ranging from 40 to 280ms, with 8 replicates for each setting. Alongside (a) the raw data, three methods of correcting for respiration were tested: (b) limiting analysis to a respiratory cycle, (c) asymmetric least squares (ALS) and (d) discrete wavelet transform (DWT). The utility of a quality control step was tested.

Results: CVP signals were a mirror image of the systolic ABP signals: The four R values were -0.674, -0.692, -0.631, -0.671 respectively (all p<0.001). With quality control, the mirror image was best for DWT (R = -0.76, p<0.001), with the CVP and ABP optima agreeing well (R = 0.78, p<0.001). The automated quality control signal correctly predicted the gap between the AVD optima calculated from ABP and CVP (R = 0.8, p<0.001).

Conclusions: Central venous pressure signals could be used to optimise AVD, because they have a reliable inverse relationship with ABP when pacemaker settings undergo protocolised testing. However, protocols need careful design to circumvent spontaneous biological variability.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Cardiac Surgical Procedures* / methods
  • Central Venous Pressure* / physiology
  • Female
  • Hemodynamics
  • Humans
  • Male
  • Middle Aged
  • Pacemaker, Artificial