Quantitation of testolactone and 4,5-dihydrotestolactone in plasma and urine using high-performance liquid chromatography

J Chromatogr. 1983 Oct 14:277:79-85. doi: 10.1016/s0378-4347(00)84825-2.

Abstract

A rapid, sensitive, and selective assay is described for the quantitation of both testolactone and its recently identified metabolite, 4,5-dihydrotestolactone, in plasma and urine using high-performance liquid chromatography. The procedure includes a methylene chloride extraction prior to chromatography and quantitation using peak height ratios (ultraviolet absorbance detection, 242 nm) of testolactone and 4,5-dihydrotestolactone to the internal standard, testosterone. A sensitivity of 20 ng/ml for both testolactone and 4,5-dihydrotestolactone is easily achieved using only 0.5 ml of sample. Mean recoveries for testolactone and its metabolite are 95.0% and 81.8%, respectively, and the mean coefficient of variation of the procedure is 3.5% for the drug and 7.1% for the metabolite. This method is currently being used to study the pharmacokinetics of testolactone and 4,5-dihydrotestolactone in male patients. A steady-state plasma concentration versus time profile from a representative patient is included.

MeSH terms

  • Chromatography, High Pressure Liquid / methods
  • Humans
  • Male
  • Testolactone / analogs & derivatives*
  • Testolactone / analysis*
  • Testolactone / blood
  • Testolactone / urine
  • Time Factors

Substances

  • 4,5-dihydrotestolactone
  • Testolactone