Five commercially available immunoassays were evaluated for the detection of Chlamydia psittaci in cloacal and conjunctival swabs from industrially raised turkeys: IMAGEN (DAKO Diagnostics, Ely, Cambridgeshire, United Kingdom), Chlamydia CEL-VET IF (Cellabs, Brookvale, Australia), IDEIA (DAKO Diagnostics), CELISA (Cellabs), and CLEARVIEW (Unipath, Bedford, United Kingdom). Results were compared with isolation in Buffalo Green Monkey cells as a reference method. For the conjunctival samples, the sensitivities of the IMAGEN test, the Chlamydia CEL-VET IF test, the IDEIA, the CELISA, and the CLEARVIEW test were found to be 100, 66, 0, 0, and 0%, respectively, as compared to the reference test. Also for the conjunctival samples, the specificities of the IMAGEN test, the Chlamydia CEL-VET IF test, and the IDEIA were found to be 100, 11, and 92.8%, respectively. For the cloacal specimens, the sensitivities of the IMAGEN test, the Chlamydia CEL-VET IF test, the IDEIA, the CELISA, and the CLEARVIEW test were found to be 100, 93.3, 26.6, 0, and 53.3%, respectively. Also for the cloacal specimens, the specificities of the IMAGEN test, the Chlamydia CEL-VET IF test, the IDEIA, and the CLEARVIEW test were found to be 92, 12, 100, and 88%, respectively. The IMAGEN test was the most sensitive and specific direct chlamydia antigen detection test for cloacal and conjunctival samples from turkeys.