Activation of coagulation and fibrinolytic pathways in patients with left ventricular assist devices

J Thorac Cardiovasc Surg. 1996 Oct;112(4):1090-7. doi: 10.1016/S0022-5223(96)70111-3.

Abstract

Left ventricular assist devices have provided successful supportive therapy for patients awaiting cardiac transplantation for extended periods of time. Although thromboembolic events have complicated support with these devices, the HeartMate left ventricular assist device developed by Thermo Cardiosystems, Inc., Woburn, Massachusetts, was specifically designed with a textured blood-contacting surface to minimize this risk. Clinical experience with this device has been encouraging, inasmuch as minimal thromboembolic complications have occurred despite the absence of anticoagulation. The coagulation and fibrinolytic pathways in these individuals were investigated to better understand the hematologic status of patients treated with the Thermo Cardiosystems device. Despite apparently normal prothrombin and activated partial thromboplastin times, as well as platelet counts, evidence of significant thrombin generation and fibrinolysis was present. To eliminate underlying cardiac failure as the responsible factor for these abnormalities, we made similar measurements in patients with end-stage heart failure who were not supported by an assist device or anticoagulation. These measurements revealed no evidence of thrombin generation or fibrinolysis. These data demonstrate that patients supported with a left ventricular assist device, while successfully sustained without systemic anticoagulation, nevertheless have evidence of activation of coagulation. These phenomena appear to be related to the presence of the device rather than to the underlying cardiac abnormalities. Although procoagulant and fibrinolytic pathways are apparently balanced in these patients, these data underscore the potential for the development of bleeding or thrombosis in clinically relevant settings.

Publication types

  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Antithrombin III / analysis
  • Blood Coagulation*
  • Female
  • Fibrinogen / analysis
  • Fibrinolysis*
  • Heart-Assist Devices / adverse effects*
  • Humans
  • Male
  • Middle Aged
  • Partial Thromboplastin Time
  • Peptide Fragments / analysis
  • Peptide Hydrolases / analysis
  • Platelet Count
  • Prothrombin / analysis
  • Prothrombin Time
  • Risk Factors
  • Thromboembolism / diagnosis
  • Thromboembolism / etiology

Substances

  • Peptide Fragments
  • antithrombin III-protease complex
  • prothrombin fragment 1.2
  • Antithrombin III
  • Prothrombin
  • Fibrinogen
  • Peptide Hydrolases