Hypertension in pregnancy: which method of blood pressure measurement is most predictive of outcome?

Obstet Gynecol. 1996 Dec;88(6):1030-3. doi: 10.1016/S0029-7844(96)00350-X.

Abstract

Objective: To determine the clinical effectiveness of blood pressure (BP) measurement using conventional sphygmomanometry in the antenatal clinic and obstetric day unit compared with automated BP monitoring at home.

Methods: The study population consisted of 109 nulliparous white women with BPs of at least 140 or 90 mmHg at the antenatal clinic after 20 weeks' gestation, who underwent obstetric day unit and 24-hour automated BP monitoring on the same day. Automated measurement was obtained every half hour for 24 hours using a commercially available device that had been previously validated in pregnancy.

Results: At the traditional BP cutoff point (140/90 mmHg), the relative risk for subsequent development of adverse obstetric outcome was greatest for automated BP measurement: The relationships between outcome and automated diastolic BP were all statistically significant: proteinuria (P = .034), preterm delivery (P < .001), birth weight below the tenth percentile (P = .001), admission to the special care neonatal unit (P = .001), and cesarean delivery (P = .007).

Conclusion: Automated BP measurement appears to improve the identification of patients who are at high risk of poor obstetric outcome. Automated BP measurement is worthy of further evaluation as an antenatal screening and diagnostic test.

Publication types

  • Clinical Trial
  • Comparative Study

MeSH terms

  • Adolescent
  • Adult
  • Blood Pressure Determination / instrumentation
  • Blood Pressure Determination / methods*
  • Blood Pressure Monitoring, Ambulatory
  • Female
  • Humans
  • Hypertension / diagnosis*
  • Predictive Value of Tests
  • Pregnancy
  • Pregnancy Complications, Cardiovascular / diagnosis*
  • Pregnancy Outcome*
  • Sensitivity and Specificity