Technetium-99m-MIBI and thallium-201 scintigraphy of primary lung cancer

J Nucl Med. 1997 Sep;38(9):1358-61.

Abstract

We evaluated the usefulness of 99mTc-MIBI scintigraphy in primary lung cancer in comparison with 201Tl-chloride scintigraphy.

Methods: There were 45 patients with primary lung cancer. All patients underwent dual-isotope imaging with 201Tl-chloride and 99mTc-MIBI. Regions of interest were placed over the tumors (T) and contralateral normal lung tissue (N) on one coronal view in the SPECT, and T/N ratio and retention index were calculated.

Results: The positive rate was 98% in both the early and delayed images for 201Tl-chloride and 96% in the early and 89% in the delayed image for 99mTc-MIBI. Both early and delayed T/N ratios for 201Tl-chloride were higher than those for 99mTc-MIBI. There was no significant correlation between T/N ratio and histological type of tumor in both images. However, in both images, there was a tendency for the early and delayed ratios to increase as the tumor diameter became larger. The retention index of 201Tl-chloride was higher than that of 99mTc-MIBI. There were no significant differences in the retention index with respect to the histological type and tumor size.

Conclusion: The results of this preliminary clinical study suggest that 99mTl-MIBI can depict primary lung cancer similar to 201Tl-chloride. However, T/N ratio and retention index of 99mTc-MIBI in the tumor areas are significantly lower compared with those of 201Tl-chloride.

Publication types

  • Case Reports
  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Female
  • Humans
  • Lung / diagnostic imaging
  • Lung Neoplasms / diagnostic imaging*
  • Male
  • Middle Aged
  • Sensitivity and Specificity
  • Technetium Tc 99m Sestamibi*
  • Thallium Radioisotopes*
  • Tomography, Emission-Computed, Single-Photon

Substances

  • Thallium Radioisotopes
  • Technetium Tc 99m Sestamibi