Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

191 results

Filters applied: . Clear all
Results are displayed in a computed author sort order. The Publication Date timeline is not available.
Page 1
Long-term complications related to biventricular defibrillator implantation: rate of surgical revisions and impact on survival: insights from the Italian Clinical Service Database.
Landolina M, Gasparini M, Lunati M, Iacopino S, Boriani G, Bonanno C, Vado A, Proclemer A, Capucci A, Zucchiatti C, Valsecchi S, Ricci RP, Santini M; Cardiovascular Centers Participating in the ClinicalService Project. Landolina M, et al. Among authors: iacopino s. Circulation. 2011 Jun 7;123(22):2526-35. doi: 10.1161/CIRCULATIONAHA.110.015024. Epub 2011 May 16. Circulation. 2011. PMID: 21576653 Clinical Trial.
Usefulness of echo-guided cardiac resynchronization pacing in patients undergoing "ablate and pace" therapy for permanent atrial fibrillation and effects of heart rate regularization and left ventricular resynchronization.
Brignole M, Menozzi C, Botto GL, Mont L, Osca Asensi J, García Medina D, Oddone D, Navazio A, Luzi M, Iacopino S, De Fabrizio G, Proclemer A, Vardas P. Brignole M, et al. Among authors: iacopino s. Am J Cardiol. 2008 Oct 1;102(7):854-60. doi: 10.1016/j.amjcard.2008.05.024. Epub 2008 Jul 9. Am J Cardiol. 2008. PMID: 18805110
Implantable CRT device diagnostics identify patients with increased risk for heart failure hospitalization.
Perego GB, Landolina M, Vergara G, Lunati M, Zanotto G, Pappone A, Lonardi G, Speca G, Iacopino S, Varbaro A, Sarkar S, Hettrick DA, Denaro A; Optivol-CRT Clinical Service Observational Group. Perego GB, et al. Among authors: iacopino s. J Interv Card Electrophysiol. 2008 Dec;23(3):235-42. doi: 10.1007/s10840-008-9303-5. Epub 2008 Sep 23. J Interv Card Electrophysiol. 2008. PMID: 18810621
Monitoring intrathoracic impedance with an implantable defibrillator reduces hospitalizations in patients with heart failure.
Catanzariti D, Lunati M, Landolina M, Zanotto G, Lonardi G, Iacopino S, Oliva F, Perego GB, Varbaro A, Denaro A, Valsecchi S, Vergara G; Italian Clinical Service Optivol-CRT Group. Catanzariti D, et al. Among authors: iacopino s. Pacing Clin Electrophysiol. 2009 Mar;32(3):363-70. doi: 10.1111/j.1540-8159.2008.02245.x. Pacing Clin Electrophysiol. 2009. PMID: 19272067 Clinical Trial.
Cardiac resynchronization therapy in patients undergoing open-chest cardiac surgery.
Barosi A, Lunati M, Speca G, Mazzola A, Paglino G, De Bonis M, Iacopino S, Cassese M, Dicandia CD, Esposito G, Vimercati M, Della Scala A, Vitali E. Barosi A, et al. Among authors: iacopino s. J Interv Card Electrophysiol. 2011 Apr;30(3):251-9. doi: 10.1007/s10840-009-9451-2. Epub 2010 Mar 10. J Interv Card Electrophysiol. 2011. PMID: 20217466
Presence of left ventricular contractile reserve predicts midterm response to cardiac resynchronization therapy--results from the LOw dose DObutamine stress-echo test in Cardiac Resynchronization Therapy (LODO-CRT) trial.
Muto C, Gasparini M, Neja CP, Iacopino S, Davinelli M, Zanon F, Dicandia C, Distefano G, Donati R, Calvi V, Denaro A, Tuccillo B. Muto C, et al. Among authors: iacopino s. Heart Rhythm. 2010 Nov;7(11):1600-5. doi: 10.1016/j.hrthm.2010.07.036. Epub 2010 Aug 3. Heart Rhythm. 2010. PMID: 20691283 Clinical Trial.
Efficacy of a tool combining guide-wire and stylet for the left ventricular lead positioning.
Giannola G, Iacopino S, Lombardo E, Cesario A, Di Stefano G, Piraino LG, Campisi G, Torcivia R, Corrao D, Risi A, Denaro A, Valsecchi S; Italian Clinical Service Attain Hybrid Group. Giannola G, et al. Among authors: iacopino s. Europace. 2011 Feb;13(2):244-50. doi: 10.1093/europace/euq429. Epub 2010 Dec 4. Europace. 2011. PMID: 21131651
Incidence and clinical relevance of uncontrolled ventricular rate during atrial fibrillation in heart failure patients treated with cardiac resynchronization therapy.
Boriani G, Gasparini M, Landolina M, Lunati M, Proclemer A, Lonardi G, Iacopino S, Rahue W, Biffi M, DiStefano P, Grammatico A, Santini M; ClinicalService cardiac centres. Boriani G, et al. Among authors: iacopino s. Eur J Heart Fail. 2011 Aug;13(8):868-76. doi: 10.1093/eurjhf/hfr046. Epub 2011 May 10. Eur J Heart Fail. 2011. PMID: 21558331 Free article.
Low-dose dobutamine test associated with interventricular dyssynchrony: a useful tool to identify cardiac resynchronization therapy responders: data from the LOw dose DObutamine stress-echo test in Cardiac Resynchronization Therapy (LODO-CRT) phase 2 study.
Gasparini M, Muto C, Iacopino S, Zanon F, Dicandia C, Distefano G, Favale S, Peraldo Neja C, Bragato R, Davinelli M, Mangoni L, Denaro A. Gasparini M, et al. Among authors: iacopino s. Am Heart J. 2012 Mar;163(3):422-9. doi: 10.1016/j.ahj.2011.11.015. Epub 2012 Jan 20. Am Heart J. 2012. PMID: 22424013 Clinical Trial.
191 results