Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

901 results

Filters applied: . Clear all
Results are displayed in a computed author sort order. The Publication Date timeline is not available.
Page 1
An FPGA-based bolometer for the MAST-U Super-X divertor.
Lovell J, Naylor G, Field A, Drewelow P, Sharples R; JET Contributors. Lovell J, et al. Among authors: field a. Rev Sci Instrum. 2016 Nov;87(11):11E721. doi: 10.1063/1.4961556. Rev Sci Instrum. 2016. PMID: 27910527
A new resistive bolometer system has been developed for MAST-Upgrade. It will measure radiated power in the new Super-X divertor, with millisecond time resolution, along 16 vertical and 16 horizontal lines of sight. The system uses a Xilinx Zynq-7000 series Field
A new resistive bolometer system has been developed for MAST-Upgrade. It will measure radiated power in the new Super-X divertor, wit
Overview and first measurements of the MAST Upgrade bolometer diagnostic.
Lovell J, Reinke ML, Field AR, Lomanowski BA; MAST Upgrade Team. Lovell J, et al. Among authors: field ar. Rev Sci Instrum. 2023 Feb 1;94(2):023509. doi: 10.1063/5.0128750. Rev Sci Instrum. 2023. PMID: 36859004
Data are digitized and processed using novel field-programmable gate array-based electronics, offering improved compactness and new operational capabilities. A synthetic diagnostic has been developed to explore the quality of 2D reconstructions available from the sy …
Data are digitized and processed using novel field-programmable gate array-based electronics, offering improved compactness and new o …
Calculation of spatial response of 2D beam emission spectroscopy diagnostic on MAST.
Ghim Kim YC, Field AR, Zoletnik S, Dunai D. Ghim Kim YC, et al. Among authors: field ar. Rev Sci Instrum. 2010 Oct;81(10):10D713. doi: 10.1063/1.3479037. Rev Sci Instrum. 2010. PMID: 21033906
The beam emission spectroscopy (BES) turbulence diagnostic on MAST is to be upgraded in June 2010 from a one-dimensional trial system to a two-dimensional imaging system (8 radial4 poloidal channels) based on a newly developed avalanche photodiode array camer …
The beam emission spectroscopy (BES) turbulence diagnostic on MAST is to be upgraded in June 2010 from a one-dimensional trial system …
Fast scanning probe for the NSTX spherical tokamak.
Boedo JA, Crocker N, Chousal L, Hernandez R, Chalfant J, Kugel H, Roney P, Wertenbaker J; NSTX Team. Boedo JA, et al. Rev Sci Instrum. 2009 Dec;80(12):123506. doi: 10.1063/1.3266065. Rev Sci Instrum. 2009. PMID: 20073119
The probe is mounted in a fast pneumatic drive capable of speeds approximately 7 m/s and approximately 20g's acceleration in order to reach the scrape-off layer (SOL) and pedestal regions and remain inserted long enough to obtain good statistics while minimizing the heat d …
The probe is mounted in a fast pneumatic drive capable of speeds approximately 7 m/s and approximately 20g's acceleration in order to …
Experimental signatures of critically balanced turbulence in MAST.
Ghim YC, Schekochihin AA, Field AR, Abel IG, Barnes M, Colyer G, Cowley SC, Parra FI, Dunai D, Zoletnik S; MAST Team. Ghim YC, et al. Among authors: field ar. Phys Rev Lett. 2013 Apr 5;110(14):145002. doi: 10.1103/PhysRevLett.110.145002. Epub 2013 Apr 1. Phys Rev Lett. 2013. PMID: 25166998
Beam emission spectroscopy (BES) measurements of ion-scale density fluctuations in the MAST tokamak are used to show that the turbulence correlation time, the drift time associated with ion temperature or density gradients, the particle (ion) streaming time along the magnetic …
Beam emission spectroscopy (BES) measurements of ion-scale density fluctuations in the MAST tokamak are used to show that the turbulence cor …
901 results